Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 324

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Ultrasound-guided Internal Jugular Venous Cannulation in Infants: A Prospective Comparison with the Traditional Palpation Method

Open access
Verghese, Susan T., McGill, Willis A., Patel, Ramesh I., Sell, Jeffrey E., Midgley, Frank M., Ruttimann, Urs E. · 1999 · Anesthesiology

Abstract

Background: Percutaneous cannulation of the internal jugular vein in infants is technically more difficult and carries a higher risk of carotid artery puncture than in older children and adults. In this prospective study, the authors tested their hypothesis that using an ultrasound scanner would increase the success of internal jugular cannulation and decrease the incidence of carotid artery puncture in infants. Methods: After approval from the institutional review board and receipt of written informed parental consent, 95 infants scheduled for cardiac surgery were randomized prospectively into two groups. In the landmarks group, the patients' internal jugular veins were cannulated using the traditional method of palpation of carotid pulsation and identification of other anatomic landmarks. In the ultrasound group, cannulation was guided using an ultrasound scanner image. The cannulation time, number of attempts, success rate, and incidence of complications were compared for the two groups. Results: There were no significant differences between the two groups with regard to weight, age, and American Society of Anesthesiologists physical status classification. The success rate was 100% in the ultrasound group, with no carotid artery punctures, and 77% in the landmarks group, with a 25% incidence of carotid artery punctures. Both differences were significant (P > 0.0004). The cannulation time was less, the number of attempts was fewer, and the failure rate was significantly lower in the ultrasound group than in the landmark group. Conclusion: Ultrasonographic localization of the internal jugular vein was superior to the landmarks technique in terms of overall success, speed, and decreased incidence of carotid artery puncture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199907000-00013

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 324

Metadata

Authors
Verghese, S. T., McGill, W. A., Patel, R. I., Sell, J. E., Midgley, F. M., & Ruttimann, U. E.
Venue
Anesthesiology
Published
1999-07-01
Volume
91
Issue
1
Pages
71-77
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2065494400
Cited by
324
References
5
FWCI
11.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound-guided Internal Jugular Venous Cannulation in Infants: A Prospective Comparison with the Traditional Palpation Method. https://app.cochat.ai/papers/10.1097/00000542-199907000-00013
The paper
Verghese, S. T., McGill, W. A., Patel, R. I., Sell, J. E., Midgley, F. M., & Ruttimann, U. E. (1999). Ultrasound-guided Internal Jugular Venous Cannulation in Infants: A Prospective Comparison with the Traditional Palpation Method. Anesthesiology. https://doi.org/10.1097/00000542-199907000-00013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.