The DOI matches its Crossref record.
Comparison of gastric intramucosal pH with measures of oxygen transport and consumption in critically ill patients
Abstract
OBJECTIVE: To determine the relationship of tonometrically measured gastric intramucosal pH to clinically accepted indices of systemic oxygenation. DESIGN: Prospective, nonintervention study. SETTING: Medical and surgical ICUs of a university hospital. PATIENTS: Critically ill patients (n = 22) with pulmonary artery catheters in place who also required nasogastric suctioning. MEASUREMENTS AND MAIN RESULTS: Tonometric measurements of gastric intramucosal pH were compared with concurrently obtained systemic indices of tissue oxygenation. These variables included oxygen delivery (DO2), oxygen consumption (VO2), oxygen extraction ratio, arterial lactate concentrations, mixed venous PO2, and mixed venous pH. The study period ranged from the time of insertion of the pulmonary artery catheter to the time of its removal. We classified patients who were alive by the end of the study as survivors and those patients who died with the pulmonary artery catheter in place as nonsurvivors. Both groups had similar levels of DO2 during the study period, but nonsurvivors had greater levels of VO2, oxygen extraction ratio, and serum lactate concentrations than survivors. Gastric intramucosal pH, mixed venous pH, and mixed venous PO2 values were lower in nonsurvivors. Both groups demonstrated the phenomenon of oxygen supply dependency. When the final measurements taken before the removal of the pulmonary artery catheter or death were compared, only gastric intramucosal pH and mixed venous pH showed differences between the groups, being lower in nonsurvivors. All the patients who died, except for one, had final gastric intramucosal pH values of less than 7.32. CONCLUSIONS: In this group of patients, death was associated with increased tissue needs for oxygen that were not adequately satisfied by the available levels of oxygen supply. We also conclude that tonometrically measured gastric intramucosal pH is a useful noninvasive adjunct to current methods of monitoring systemic oxygenation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mythen, M. G. (1995) · Archives of Surgery · doi:10.1001/archsurg.1995.01430040085019 · Cited by 645
Antonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466
Assessment of Splanchnic Oxygenation by Gastric Tonometry in Patients With Acute Circulatory Failure
Maynard, N. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03510100053032 · Cited by 446
Mythen, M. G., & Webb, A. R. (1994) · Intensive Care Medicine · doi:10.1007/bf01707662 · Cited by 361
Marik, P. E. (1993) · Chest · doi:10.1378/chest.104.1.225 · Cited by 311
Metadata
- Authors
- GUTIERREZ, G., BISMAR, H., DANTZKER, D. R., & SILVA, N.
- Venue
- Critical Care Medicine
- Published
- 1992-04
- Volume
- 20
- Issue
- 4
- Pages
- 451-457
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2093436603
- Cited by
- 198
- References
- 0
- FWCI
- 23.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of gastric intramucosal pH with measures of oxygen transport and consumption in critically ill patients. https://app.cochat.ai/papers/10.1097/00003246-199204000-00004
- The paper
- GUTIERREZ, G., BISMAR, H., DANTZKER, D. R., & SILVA, N. (1992). Comparison of gastric intramucosal pH with measures of oxygen transport and consumption in critically ill patients. Critical Care Medicine. https://doi.org/10.1097/00003246-199204000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.