Hepatocyte culture systems for artificial liver support: Implications for critical care medicine (bioartificial liver support)
The DOI matches its Crossref record.
Abstract
OBJECTIVE: The primary purpose of this review article is to familiarize critical care practitioners with newly developing techniques of hybrid artificial liver support. Implantable and extracorporeal hepatocyte culture systems are emphasized based on their current experimental and clinical status. DATA SOURCES: Data used to prepare this document were obtained from the authors' personal files, as well as the computerized MEDLINE database. Medical headings used include: liver, artificial organs, cell culture, growth hormones, extracellular matrix, and transplantation. Only articles published in English have been cited. STUDY SELECTION: All studies are discussed in which hepatocyte culture systems have been used to support human patients with liver failure. All studies reported the patient's condition before therapy, duration of therapy, and outcome after therapy in order to be included in this review. Since the number of clinical trials is small at this time, animal studies were used to demonstrate application of other systems in the treatment of experimentally induced liver failure. Similar selection criteria were used to select animal studies for review. All initially identified human studies met these selection criteria. DATA EXTRACTION: Independent extraction by multiple observers. DATA SYNTHESIS: Liver failure, resulting from infection, drugs, or as a part of the multiple organ failure syndrome, remains a major cause of morbidity, mortality, and resource allocation. Current therapy is limited to supportive care, along with liver transplantation. Because of these therapeutic limitations, hybrid artificial liver systems have been proposed for temporary and long-term hepatic support. Several animal studies and a small number of preliminary human studies indicate that hepatocyte culture systems are capable of supporting nearly all essential hepatic functions and may supply biologically active substances that promote regeneration and repair of the damaged liver being supported. Hybrid systems may be constructed from materials that serve as immunoprotective barriers against host defenses. CONCLUSIONS: During the past decade, important progress has been made with hybrid artificial liver support systems. Cell culture technology has progressed sufficiently so that an artificial liver, composed of metabolically active hepatocytes, may be a potential reality in the foreseeable future. Both implantable and extracorporeal artificial liver support systems have been developed to provide metabolic support during acute liver failure, or to serve as a bridge to solid organ transplantation. Implantable hepatocyte systems, however, require a prolonged period for intraperitoneal engraftment and vascularization, not typically available to patients with acute liver failure. For this reason, extracorporeal hybrid designs offer the greatest hope for on-line treatment of acute liver failure. Such systems are entering the final stages of animal testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Long-term storage of tissues by cryopreservation: critical issues
Karlsson, J. O. M., & Toner, M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85562-1 · Cited by 619
Pilot–Controlled Trial of the Extracorporeal Liver Assist Device in Acute Liver Failure
Ellis, A. J., Hughes, R. D., Wendon, J. A., Dunne, J., Langley, P. G., Kelly, J. H., Gislason, G. T., Sussman, N. L., & Williams, R. (1996) · Hepatology · doi:10.1002/hep.510240625 · Cited by 513
Medical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
“The main challenge in the evelopment of a functional BALS concerns the maintenance f differentiated hepatocyte functions for prolonged periods in uch a system since hepatocytes lose their metabolic activities ithin a short period of time in vitro due to the deprivation of heir original architecture and polarity [214].”
BackgroundBiocatalytic membrane reactors: applications and perspectives
Giorno, L., & Drioli, E. (2000) · Trends in Biotechnology · doi:10.1016/s0167-7799(00)01472-4 · Cited by 370
Treatment of Hepatic Failure with ex Vivo Pig-Liver Perfusion Followed by Liver Transplantation
Chari, R. S., Collins, B. H., Magee, J. C., DiMaio, J. M., Kirk, A. D., Harland, R. C., McCann, R. L., Platt, J. L., & Meyers, W. C. (1994) · New England Journal of Medicine · doi:10.1056/nejm199407283310404 · Cited by 286
Metadata
- Authors
- NYBERG, S. L., SHATFORD, R. A., HU, W.-S., PAYNE, W. D., & CERRA, F. B.
- Venue
- Critical Care Medicine
- Published
- 1992-08
- Volume
- 20
- Issue
- 8
- Pages
- 1157-1168
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2018957603
- Cited by
- 71
- References
- 0
- FWCI
- 9.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hepatocyte culture systems for artificial liver support: Implications for critical care medicine (bioartificial liver support). https://app.cochat.ai/papers/10.1097/00003246-199208000-00016
- The paper
- NYBERG, S. L., SHATFORD, R. A., HU, W.-S., PAYNE, W. D., & CERRA, F. B. (1992). Hepatocyte culture systems for artificial liver support: Implications for critical care medicine (bioartificial liver support). Critical Care Medicine. https://doi.org/10.1097/00003246-199208000-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.