Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 275

The DOI matches its Crossref record.

Oxygen consumption and resting metabolic rate in sepsis, sepsis syndrome, and septic shock

KREYMANN, GEORG, GROSSER, SEBASTIAN, BUGGISCH, PETER, GOTTSCHALL, CLAUS, MATTHAEI, STEPHAN, GRETEN, HEINER·1993·Critical Care Medicine

Abstract

OBJECTIVE: To test the hypothesis that variations in oxygen consumption (VO2) and resting metabolic rate reflect the severity of bacterial infections and reflect the development of sepsis syndrome and septic shock. DESIGN: Observational study with sequential measurements of VO2 and resting metabolic rate by expiratory gas analysis. SETTING: Medical intensive care unit. PATIENTS: Thirty patients, treated primarily for presumed bacterial infection, were examined on 118 treatment days. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: VO2 and resting metabolic rate were measured by expiratory gas analysis. For mechanically ventilated patients, a measurement system was developed, based on a paramagnetic oxygen sensor, an infrared CO2 sensor, and digital signal averaging. Measurements in spontaneously breathing patients were performed with a metabolic monitor. Patients were assigned by clinical criteria to the following groups: sepsis, sepsis syndrome, and septic shock. The lowest VO2 value of each patient in each stage was evaluated. Mean VO2 in 15 patients with sepsis was 180 +/- 19 (SD) mL/min/m2, in 11 patients with sepsis syndrome 156 +/- 22 mL/min/m2, and in eight patients with septic shock 120 +/- 27 mL/min/m2 (p < .001). Mean resting metabolic rate in sepsis was +55 +/- 14%, in sepsis syndrome +24 +/- 12%, and in septic shock +2 +/- 24% (p < .001). Mean oxygen delivery (DO2) was 501 +/- 116 mL/min/m2 in sepsis, 515 +/- 186 mL/min/m2 in sepsis syndrome, and 404 +/- 96 mL/min/m2 in septic shock. Oxygen extraction (VO2/DO2) was highest in sepsis (0.39 vs. 0.33 in sepsis syndrome and 0.29 in septic shock). During recovery from sepsis syndrome or septic shock, a significant increase in resting metabolic rate to +61 +/- 22% was measured in nine patients. CONCLUSIONS: In sepsis syndrome, VO2 and resting metabolic rate are enhanced by 30% compared with normal basal metabolism, but they are markedly reduced compared with uncomplicated sepsis. The higher VO2 in uncomplicated sepsis is flow independent. The noninvasive measurement of VO2 and resting metabolic rate by expiratory gas analysis therefore can be used as a quantitative staging and monitoring parameter for the development of sepsis syndrome and septic shock.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199307000-00015

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 275

Metadata

Authors
KREYMANN, G., GROSSER, S., BUGGISCH, P., GOTTSCHALL, C., MATTHAEI, S., & GRETEN, H.
Venue
Critical Care Medicine
Published
1993-07
Volume
21
Issue
7
Pages
1012-1019
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1999742427
Cited by
275
References
0
FWCI
4.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oxygen consumption and resting metabolic rate in sepsis, sepsis syndrome, and septic shock. https://app.cochat.ai/papers/10.1097/00003246-199307000-00015
The paper
KREYMANN, G., GROSSER, S., BUGGISCH, P., GOTTSCHALL, C., MATTHAEI, S., & GRETEN, H. (1993). Oxygen consumption and resting metabolic rate in sepsis, sepsis syndrome, and septic shock. Critical Care Medicine. https://doi.org/10.1097/00003246-199307000-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.