Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 188

The DOI matches its Crossref record.

Delivery and monitoring of inhaled nitric oxide in patients with pulmonary hypertension

WESSEL, DAVID L., ADATIA, IAN, THOMPSON, JOHN E., HICKEY, PAUL R. · 1994 · Critical Care Medicine

Abstract

OBJECTIVE: The development of a safe, portable, accurate, and adaptable system to deliver nitric oxide to patients with pulmonary hypertension. DESIGN: A prospective, clinical study. SETTING: Tertiary care pediatric intensive care unit and cardiac catheterization laboratory. PATIENTS: One hundred twenty-three patients (median age 11 months, range 1 day to 72 yrs) with pulmonary hypertension who were administered nitric oxide between November 1991 and July 1993. Ninety-one patients were mechanically ventilated (volume-controlled ventilator, n = 53; pressure-controlled ventilator, n = 5; and a pressure-limited, time-cycled infant ventilator, n = 25). The system was adapted to allow high-frequency oscillator (n = 2) or hand ventilation, and for intraoperative use with an anesthesia machine (n = 6). Thirty-two patients were breathing spontaneously through a mask without assistance. INTERVENTIONS: Nitric oxide was delivered at 10 to 80 parts per million (ppm); the dose was adjusted independently of the FIO2 without altering minute ventilation or tidal volume. MEASUREMENTS AND MAIN RESULTS: Nitrogen dioxide was continuously monitored and exceeded 3 ppm in only four patients. Methemoglobin concentrations were < 5% in all but four patients. Nitric oxide doses remained stable, independent of minute ventilation and could be changed easily and quickly. CONCLUSIONS: Inhaled nitric oxide can be administered precisely and reliably through a variety of delivery systems which can be used in patients of any size. Potential toxicity requires careful monitoring and continued improvement on apparatus design.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199406000-00009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
WESSEL, D. L., ADATIA, I., THOMPSON, J. E., & HICKEY, P. R.
Venue
Critical Care Medicine
Published
1994-06
Volume
22
Issue
6
Pages
930-938
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2040537249
Cited by
188
References
0
FWCI
38.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Delivery and monitoring of inhaled nitric oxide in patients with pulmonary hypertension. https://app.cochat.ai/papers/10.1097/00003246-199406000-00009
The paper
WESSEL, D. L., ADATIA, I., THOMPSON, J. E., & HICKEY, P. R. (1994). Delivery and monitoring of inhaled nitric oxide in patients with pulmonary hypertension. Critical Care Medicine. https://doi.org/10.1097/00003246-199406000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.