The DOI matches its Crossref record.
Delivery and monitoring of inhaled nitric oxide in patients with pulmonary hypertension
Abstract
OBJECTIVE: The development of a safe, portable, accurate, and adaptable system to deliver nitric oxide to patients with pulmonary hypertension. DESIGN: A prospective, clinical study. SETTING: Tertiary care pediatric intensive care unit and cardiac catheterization laboratory. PATIENTS: One hundred twenty-three patients (median age 11 months, range 1 day to 72 yrs) with pulmonary hypertension who were administered nitric oxide between November 1991 and July 1993. Ninety-one patients were mechanically ventilated (volume-controlled ventilator, n = 53; pressure-controlled ventilator, n = 5; and a pressure-limited, time-cycled infant ventilator, n = 25). The system was adapted to allow high-frequency oscillator (n = 2) or hand ventilation, and for intraoperative use with an anesthesia machine (n = 6). Thirty-two patients were breathing spontaneously through a mask without assistance. INTERVENTIONS: Nitric oxide was delivered at 10 to 80 parts per million (ppm); the dose was adjusted independently of the FIO2 without altering minute ventilation or tidal volume. MEASUREMENTS AND MAIN RESULTS: Nitrogen dioxide was continuously monitored and exceeded 3 ppm in only four patients. Methemoglobin concentrations were < 5% in all but four patients. Nitric oxide doses remained stable, independent of minute ventilation and could be changed easily and quickly. CONCLUSIONS: Inhaled nitric oxide can be administered precisely and reliably through a variety of delivery systems which can be used in patients of any size. Potential toxicity requires careful monitoring and continued improvement on apparatus design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Abman, S. H., Hansmann, G., Archer, S. L., Ivy, D. D., Adatia, I., Chung, W. K., Hanna, B. D., Rosenzweig, E. B., Raj, J. U., Cornfield, D., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000329 · Cited by 1,164
Self-citationPediatric Pulmonary Hypertension
Ivy, D. D., Abman, S. H., Barst, R. J., Berger, R. M. F., Bonnet, D., Fleming, T. R., Haworth, S. G., Raj, J. U., Rosenzweig, E. B., Schulze Neick, I., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.028 · Cited by 536
Davidson, D., Barefield, E. S., Kattwinkel, J., Dudell, G., Damask, M., Straube, R., Rhines, J., Chang, C.-T., & the I-NO/PPHN Study Group (1998) · Pediatrics · doi:10.1542/peds.101.3.325 · Cited by 354
The Toxicology of Inhaled Nitric Oxide
Weinberger, B. (2001) · Toxicological Sciences · doi:10.1093/toxsci/59.1.5 · Cited by 341
Enhanced S -Nitroso-Albumin Formation From Inhaled NO During Ischemia/Reperfusion
Ng, E. S. M., Jourd’heuil, D., McCord, J. M., Hernandez, D., Yasui, M., Knight, D., & Kubes, P. (2004) · Circulation Research · doi:10.1161/01.res.0000117771.63140.d6 · Cited by 97
Metadata
- Authors
- WESSEL, D. L., ADATIA, I., THOMPSON, J. E., & HICKEY, P. R.
- Venue
- Critical Care Medicine
- Published
- 1994-06
- Volume
- 22
- Issue
- 6
- Pages
- 930-938
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2040537249
- Cited by
- 188
- References
- 0
- FWCI
- 38.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Delivery and monitoring of inhaled nitric oxide in patients with pulmonary hypertension. https://app.cochat.ai/papers/10.1097/00003246-199406000-00009
- The paper
- WESSEL, D. L., ADATIA, I., THOMPSON, J. E., & HICKEY, P. R. (1994). Delivery and monitoring of inhaled nitric oxide in patients with pulmonary hypertension. Critical Care Medicine. https://doi.org/10.1097/00003246-199406000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.