Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 263

The DOI matches its Crossref record.

Nasal mechanical ventilation for hypercapnic respiratory failure in chronic obstructive pulmonary disease: Determinants of success and failure

SOO HOO, GUY W., SANTIAGO, SILVERIO, WILLIAMS, ADRIAN J.·1994·Critical Care Medicine

Abstract

OBJECTIVES: To evaluate the efficacy of nasal mechanical ventilation in patients with chronic obstructive pulmonary disease and hypercapnic respiratory failure and to identify predictors of success or failure of nasal mechanical ventilation. DESIGN: Prospective case series. SETTING: Medical intensive care unit in Veterans Administration Medical Center. PATIENTS: Twelve chronic obstructive pulmonary disease patients treated during 14 episodes of hypercapnic respiratory failure. INTERVENTIONS: Nasal mechanical ventilation in addition to conventional therapy to treat hypercapnic respiratory failure. Patients underwent nasal mechanical ventilation for at least 30 mins, or longer if the therapy was tolerated. Responses to therapy and arterial blood gases were monitored. MEASUREMENTS AND MAIN RESULTS: Half of the episodes were successfully treated with nasal mechanical ventilation. There were no differences in age, prior pulmonary function, baseline arterial blood gases, admission arterial blood gases, or respiratory rate between those patients successfully treated and those patients who failed nasal mechanical ventilation. Unsuccessfully treated patients appeared to have a greater severity of illness than successfully treated patients, as indicated by a higher Acute Physiology and Chronic Health Evaluation II score (mean 21 +/- 4 [SD] vs. 15 +/- 4; p = .02). Unsuccessfully treated patients were edentulous, had pneumonia or excess secretions, and had pursed-lip breathing, factors that prevented adequate mouth seal and contributed to greater mouth leaks than in successfully treated patients (the mean volume of the mouth leak was 314 +/- 107 vs. 100 +/- 70 mL; p < .01). Successfully treated patients were able to adapt more rapidly to the nasal mask and ventilator, with greater and more rapid reduction in PaCO2, correction of pH, and reduction in respiratory rate. CONCLUSIONS: Patients who failed nasal mechanical ventilation appeared to have a greater severity of illness; they were unable to minimize the amount of mouth leak (because of lack of teeth, secretions, or breathing pattern) and were unable to coordinate with the ventilator. These features may allow identification of poor candidates for nasal mechanical ventilation, avoiding unnecessary delays in endotracheal intubation and mechanical ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199408000-00009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 263

Metadata

Authors
SOO HOO, G. W., SANTIAGO, S., & WILLIAMS, A. J.
Venue
Critical Care Medicine
Published
1994-08
Volume
22
Issue
8
Pages
1253-1261
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2085170482
Cited by
263
References
0
FWCI
8.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nasal mechanical ventilation for hypercapnic respiratory failure in chronic obstructive pulmonary disease: Determinants of success and failure. https://app.cochat.ai/papers/10.1097/00003246-199408000-00009
The paper
SOO HOO, G. W., SANTIAGO, S., & WILLIAMS, A. J. (1994). Nasal mechanical ventilation for hypercapnic respiratory failure in chronic obstructive pulmonary disease: Determinants of success and failure. Critical Care Medicine. https://doi.org/10.1097/00003246-199408000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.