The DOI matches its Crossref record.
Noninvasive mechanical ventilation via face mask in patients with acute respiratory failure who refused endotracheal intubation
Abstract
OBJECTIVE: To evaluate the response to noninvasive ventilation in a group of terminally ill patients with acute respiratory failure who refused endotracheal intubation. DESIGN: Case series. SETTING: Medical intensive care units (ICUs) in a university health science center. PATIENTS: Eleven patients, nine with hypercapnic and two with hypoxemic acute respiratory failure. Mean age of patients was 64 yrs. INTERVENTION: Mechanical ventilation was delivered via a face mask. The initial ventilatory setting was continuous positive airway pressure mode, with pressure-support ventilation of 10 to 20 cm H2O, titrated to achieve a respiratory rate of < 25 breaths/min and a tidal volume of 5 to 7 mL/kg. Ventilatory settings were adjusted based on results of arterial blood gases. Mean duration of mechanical ventilation was 44 hrs. MEASUREMENTS AND MAIN RESULTS: Mechanical ventilation via face mask was effective in correcting gas exchange abnormalities in seven of 11 patients, all of whom survived and were discharged from the ICU. Four patients with hypercapnic acute respiratory failure died. Mechanical ventilation via face mask was effective in improving respiratory acidosis in three patients and had no effect in one patient. Two of the four patients could not be weaned from mechanical ventilation and opted for discontinuation of this method. Removal of the ventilator while retaining the mask for oxygen supplementation was a nontraumatic experience to the patient and family. Even when respiratory failure did not resolve, mechanical ventilation via face mask was effective in lessening dyspnea and allowed the patient to maintain autonomy and continuous verbal communication. CONCLUSIONS: We conclude that mechanical ventilation via face mask offers an effective, comfortable, and dignified method of supporting patients with end-stage disease and acute respiratory failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kramer, N., Meyer, T. J., Meharg, J., Cece, R. D., & Hill, N. S. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.6.7767523 · Cited by 915
Time of non-invasive ventilation
Nava, S., Navalesi, P., & Conti, G. (2006) · Intensive Care Medicine · doi:10.1007/s00134-005-0050-0 · Cited by 144
Metadata
- Authors
- Meduri, U. G., Fox, R. C., Abou-Shala, N., Leeper, K. V., & Wunderink, R. G.
- Venue
- Critical Care Medicine
- Published
- 1994-10
- Volume
- 22
- Issue
- 10
- Pages
- 1584-1590
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1998576024
- Cited by
- 192
- References
- 0
- FWCI
- 6.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive mechanical ventilation via face mask in patients with acute respiratory failure who refused endotracheal intubation. https://app.cochat.ai/papers/10.1097/00003246-199410000-00013
- The paper
- Meduri, U. G., Fox, R. C., Abou-Shala, N., Leeper, K. V., & Wunderink, R. G. (1994). Noninvasive mechanical ventilation via face mask in patients with acute respiratory failure who refused endotracheal intubation. Critical Care Medicine. https://doi.org/10.1097/00003246-199410000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.