Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Variability of indices of hypoxemia in adult respiratory distress syndrome

Gowda, Madhu S., Klocke, Robert A. · 1997 · Critical Care Medicine

Abstract

OBJECTIVE: To determine the usefulness of indices of hypoxemia in assessing patients with the adult respiratory distress syndrome (ARDS). DESIGN: Retrospective analysis of previously published data that describe the distributions of ventilation and pulmonary blood flow in ARDS. SETTING: University research laboratory. PATIENTS: Sixteen patients with ARDS. INTERVENTIONS: The FIO2 was varied between 0.21 and 1.0 in a computer model of gas exchange, based on a 50-compartment model of ventilation/perfusion inhomogeneity plus true shunt and deadspace. The indices of hypoxemia that were calculated as a function of inspired oxygen concentration included PaO2/FIO2, arterial/alveolar ratio (PaO2/alveolar PO2), the alveolar-arterial PO2 difference (P[A-a]O2), respiratory index (P[A-a]O2/PaO2), and venous admixture. MEASUREMENTS AND MAIN RESULTS: The PaO2/FIO2 ratio in patients with moderate shunts (< 30%) varied considerably with alteration in FIO2. At both extremes of FIO2, the PaO2/FIO2 in these patients was substantially greater than at intermediate FIO2. Patients with larger shunts (> 30%) had greater PaO2/FIO2 ratios at low FIO2, but the PaO2/FIO2 ratios decreased to relatively stable values at FIO2 values of > 0.5. In all patients, PaO2/FIO2 remained relatively stable at FIO2 values of > or = 0.5 and PaO2 values of < or = 100 torr (< or = 13.3 kPa). Other PO2-based indices exhibited less stability as FIO2 was varied. If hypoxemia resulted from true shunting, venous admixture was found to be stable at all FIO2 values. However, approximately one half of patients had clinically important hypoxemia resulting from mismatching of ventilation and blood flow. In these patients, venous admixture varied substantially with change in FIO2, and the degree of variation was proportional to the fraction of cardiac output perfusing gas exchange units with ventilation/perfusion ratios of < 0.1. CONCLUSIONS: All indices of hypoxemia are affected by changes in FIO2 in patients with ARDS. PaO2/FIO2 ratio exhibits the most stability at FIO2 values of > or = 0.5 and PaO2 values of < or = 100 torr (< or = 13.3 kPa), and is a useful estimation of the degree of gas exchange abnormality under usual clinical conditions. Venous admixture varies substantially with alteration of FIO2 in patients who have clinically important ventilation/perfusion abnormalities. Under these circumstances, venous admixture is a poor indicator of the efficiency of pulmonary oxygen exchange, even if venous admixture is calculated from measured arterial and venous oxygen content values. Estimated venous admixture, based on an assumed arterial-venous oxygen content difference, is even more unreliable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199701000-00010

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 159

Metadata

Authors
Gowda, M. S., & Klocke, R. A.
Venue
Critical Care Medicine
Published
1997-01
Volume
25
Issue
1
Pages
41-45
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1979794865
Cited by
159
References
1
FWCI
4.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variability of indices of hypoxemia in adult respiratory distress syndrome. https://app.cochat.ai/papers/10.1097/00003246-199701000-00010
The paper
Gowda, M. S., & Klocke, R. A. (1997). Variability of indices of hypoxemia in adult respiratory distress syndrome. Critical Care Medicine. https://doi.org/10.1097/00003246-199701000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.