CoChat

Transfusing red blood cells stored in citrate phosphate dextrose adenine-1 for 28 days fails to improve tissue oxygenation in rats

Fitzgerald, Robert D., Martin, Claudio M., Dietz, Glen E., Doig, Gordon S., Potter, Richard F., Sibbald, William J. · 1997 · Critical Care Medicine
Cited by 230

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine whether the time that red blood cells are stored in citrate phosphate dextrose adenine-1 solution before transfusion alters the ability to improve tissue oxygenation. DESIGN: Prospective, randomized, controlled study. SETTING: University research institute laboratory. SUBJECTS: Male Sprague-Dawley rats (350 to 450 g). INTERVENTIONS: Twenty-four hours after randomization to sham laparotomy (n = 21) or cecal ligation and perforation (n = 16)1 supply-dependency of systemic oxygen uptake (VO2) was induced in rats by isovolemic hemodilution. Rats were then re-randomized to receive either rat red blood cells stored in citrate phosphate dextrose adenine-1 for 3 days ("fresh" n = 17) or rat red blood cells stored in citrate phosphate dextrose adenine-1 for 28 days ("old" n = 20). MEASUREMENTS AND MAIN RESULTS: Changes in systemic VO2 were measured for 90 mins to determine the efficiacy of the treatment. Statistical analysis included a fully factorial repeated-measures, generalized linear model. No significant interaction was found between cecal ligation and perforation or sham animals and transfusion with fresh or old red blood cells. However, comparing the combined groups of animals receiving either fresh or old red blood cells, we found that after the transfusion of old red blood cells, systemic VO2 was not significantly improved (after hemodilution 1.68 +/- 0.27 mL/100 g/min, after transfusion 1.86 +/- 0.17 mL/100 g/min; p > .05). In contrast, transfusion with fresh red blood cells acutely increased systemic VO2 (after hemodilution 1.62 +/- 0.06 mL/100 g/min, after transfusion 2.10 +/- 0.09 mL/100 g/min; p = .049). CONCLUSION: Storage of rat red blood cells for 28 days in citrate phosphate dextrose adenine-1 impaired their ability to improve tissue oxygenation when transfused into either control or septic rats placed into supply dependency of systemic VO2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199705000-00004

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 230

Metadata

Authors
Fitzgerald, R. D., Martin, C. M., Dietz, G. E., Doig, G. S., Potter, R. F., & Sibbald, W. J.
Venue
Critical Care Medicine
Published
1997-05
Volume
25
Issue
5
Pages
726-732
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2057703018
Cited by
230
References
14
FWCI
8.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.