Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 239

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The first decade of continuous monitoring of jugular bulb oxyhemoglobin saturation: Management strategies and clinical outcome

Cruz, Julio·1998·Critical Care Medicine

Abstract

Objective: To comparatively assess outcome of patients undergoing monitoring and management of cerebral extraction of oxygen along with cerebral perfusion pressure vs. outcome of patients undergoing monitoring and management of cerebral perfusion pressure alone in severe acute brain trauma. Design: Prospective, interventional study. Setting: Intensive care unit of a university hospital. Patients: Adults (n = 353) with severe acute brain trauma. A group of 178 patients underwent continuous monitoring and management of cerebral extraction of oxygen and cerebral perfusion pressure, while a control group of 175 patients underwent monltoring and management of cerebral perfusion pressure only. Interventions: Routine neuroemergency procedures. Measurements and Main Results: The two groups of patients were matched with regard to age, postresuscitation Glasgow Coma Scale scores, rates of acute surgical intracranial hematomas and brain swelling, pupillary abnormalities, early hypotensive events (before intensive care monitoring), as well as initial levels of intracranial pressure and cerebral perfusion pressure. Outcome at 6 months post injury was significantly better (p < .00005) in the 178 patients undergoing monitoring and management of cerebral extraction of oxygen along with cerebral perfusion pressure, than in the control group of 175 patients undergoing monitoring and management of cerebral perfusion pressure alone. Conclusion: In patients with severe acute brain trauma and intracranial hypertension associated with compromised cerebrospinal fluid spaces, monitoring and managing cerebral extraction of oxygen in conjunction with cerebral perfusion pressure result in better outcome than when cerebral perfusion pressure is managed alone. (Crit Care Med 1998; 26:344-351) Continuous fiberoptic monitoring of jugular bulb oxyhemoglobin saturation was first introduced by our team [1] in Critical Care Medicine approximately one decade ago. Over the years, a broad spectrum of newly derived physiologic variables and concepts have become available from the above-mentioned monitoring technique. The new variables include the cerebral extraction of oxygen [2-11], cerebral consumption of oxygen [7], systemic-cerebral oxygenation index and systemic-cerebral ventilatory index [8], and modified cerebral lactate-oxygen index [12]. Newly derived concepts include the cerebral hemodynamic reserve [4,6] and cerebral hemometabolic regulation [9]. The main findings reported from jugular monitoring during neuro intensive care concerned: a) oligemic cerebral hypoxia and related intracranial pressure problems[1,3,4,11,13,14]; b) relative cerebral hyperperfusion (reciprocal of oligemic hypoxia) and related intracranial pressure problems [4,5,8-11]; c) hypoxemic cerebral hypoxia [1,2,15]; and d) cerebral pressure autoregulatory abnormalities in relation to cerebral extraction of oxygen [16]. Regarding related therapeutic applications, the four main findings previously reported were those concerning: a) the combined effects of mannitol boluses in simultaneously normalizing increased intracranial pressure and cerebral extraction of oxygen [3]; b) the combined effects of optimized hyperventilation in simultaneously normalizing increased intracranial pressure and decreased cerebral extraction of oxygen [8]; c) the combined effects of optimized hyperventilation in simultaneously normalizing (matching) cerebral extraction of oxygen and glucose [10]; and d) the potential adverse effects of pentobarbital boluses, inducing transient oligemic cerebral hypoxia in some patients [14]. The present work is an expansion of our previous experience. This time an attempt was made to comparatively evaluate the outcome of severely brain-injured patients undergoing monitoring and management of cerebral extraction of oxygen in conjunction with cerebral perfusion pressure vs. patients subjected to monitoring and management of cerebral perfusion pressure alone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199802000-00039

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 239

Metadata

Authors
Cruz, J.
Venue
Critical Care Medicine
Published
1998-02
Volume
26
Issue
2
Pages
344-351
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2017809855
Cited by
239
References
1
FWCI
15.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The first decade of continuous monitoring of jugular bulb oxyhemoglobin saturation: Management strategies and clinical outcome. https://app.cochat.ai/papers/10.1097/00003246-199802000-00039
The paper
Cruz, J. (1998). The first decade of continuous monitoring of jugular bulb oxyhemoglobin saturation: Management strategies and clinical outcome. Critical Care Medicine. https://doi.org/10.1097/00003246-199802000-00039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.