The DOI matches its Crossref record.
Comparison of jugular venous oxygen saturation and brain tissue PO2 as monitors of cerebral ischemia after head injury
Abstract
OBJECTIVE: To compare the characteristics of jugular venous oxygen saturation (Sjvo2) and brain tissue Po2 (Pbto2) as monitors for cerebral ischemia after severe head injury. Sjvo2 has been useful as a monitor for cerebral ischemia, but it is limited by its inability to identify regional cerebral ischemia. Pbto2 may be superior to Sjvo2 for this purpose, because oxygenation in localized areas of the brain can be monitored. DESIGN: Sjvo2 and Pbto2 were successfully monitored in 58 patients with severe head injury. The changes in Sjvo2 and Pbto2 were compared during ischemic episodes. SETTING: Neurosurgical intensive care unit of a level I trauma center. MEASUREMENTS AND MAIN RESULTS: During the monitoring period, which averaged 90 hrs/patient, there were 54 episodes during which Sjvo2 decreased to <50% and/or Pbto2 decreased to <8 torr. Two of these episodes were caused by an infarction in the area of the Po2 probe, leaving 52 episodes of global hypoxia/ischemia that were identified by one of the two monitors. The sensitivities of the two monitors for detecting ischemia, using the thresholds of 50% and 8 torr for Sjvo2 and Pbto2, respectively, were similar. The Sjvo2 catheter detected 69.7% of the episodes and the Pbto2 catheter detected 63.5% of the episodes. In most of the remaining episodes, both probes reflected a decrease in oxygenation, but not to levels below the defined thresholds. The major differences in the two measures of oxygenation included the following: a) Sjvo2 more consistently reflected a reduction in oxygenation during hyperventilation; b) Pbto2 was affected more by changes in arterial Po2; and c) during severe global ischemia, Pbto2 decreased to 0 and remained at 0, whereas Sjvo2 initially decreased but then increased again as cerebral blood flow ceased, and the only blood in the jugular bulb was of extracerebral origin. CONCLUSIONS: The two monitors provide complimentary information, and neither monitor alone identifies all episodes of ischemia. The best strategy for using these monitors is to take advantage of the unique features of each monitor. Sjvo2 should be used as a monitor of global oxygenation; but Pbto2 should be used as a monitor of local oxygenation, ideally with the catheter placed in an area of the brain that is vulnerable to ischemia but that may be salvageable with appropriate treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vespa, P., Bergsneider, M., Hattori, N., Wu, H.-M., Huang, S.-C., Martin, N. A., Glenn, T. C., McArthur, D. L., & Hovda, D. A. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600073 · Cited by 638
Stiefel, M. F., Spiotta, A., Gracias, V. H., Garuffe, A. M., Guillamondegui, O., Maloney-Wilensky, E., Bloom, S., Grady, M. S., & LeRoux, P. D. (2005) · Journal of Neurosurgery · doi:10.3171/jns.2005.103.5.0805 · Cited by 429
Cerebral perturbations provoked by prolonged exercise
Nybo, L., & Secher, N. H. (2004) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2004.03.005 · Cited by 398
Metadata
- Authors
- Gopinath, S. P., Valadka, A. B., Uzura, M., & Robertson, C. S.
- Venue
- Critical Care Medicine
- Published
- 1999-11
- Volume
- 27
- Issue
- 11
- Pages
- 2337-2345
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2148304035
- Cited by
- 173
- References
- 0
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of jugular venous oxygen saturation and brain tissue PO2 as monitors of cerebral ischemia after head injury. https://app.cochat.ai/papers/10.1097/00003246-199911000-00003
- The paper
- Gopinath, S. P., Valadka, A. B., Uzura, M., & Robertson, C. S. (1999). Comparison of jugular venous oxygen saturation and brain tissue PO2 as monitors of cerebral ischemia after head injury. Critical Care Medicine. https://doi.org/10.1097/00003246-199911000-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.