CoChat

Efficacy of recombinant human erythropoietin in the critically ill patient: A randomized, double-blind, placebo-controlled trial

Corwin, Howard L., Gettinger, Andrew, Rodriguez, Robert M., Pearl, Ronald G., Gubler, K. Dean, Enny, Christopher, Colton, Theodore, Corwin, Michael J. · 1999 · Critical Care Medicine
Cited by 351

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine whether the administration of recombinant human erythropoietin (rHuEPO) to critically ill patients in the intensive care unit (ICU) would reduce the number of red blood cell (RBC) transfusions required. DESIGN: A prospective, randomized, double-blind, placebo-controlled, multicenter trial. SETTING: ICUs at three academic tertiary care medical centers. PATIENTS: A total of 160 patients who were admitted to the ICU and met the eligibility criteria were enrolled in the study (80 into the rHuEPO group; 80 into the placebo group). INTERVENTIONS: Patients were randomized to receive either rHuEPO or placebo. The study drug (300 units/kg of rHuEPO or placebo) was administered by subcutaneous injection beginning ICU day 3 and continuing daily for a total of 5 days (until ICU day 7). The subsequent dosing schedule was every other day to achieve a hematocrit (Hct) concentration of >38%. The study drug was given for a minimum of 2 wks or until ICU discharge (for subjects with ICU lengths of stay >2 wks) up to a total of 6 wks (42 days) postrandomization. MEASUREMENTS AND MAIN RESULTS: The cumulative number of units of RBCs transfused was significantly less in the rHuEPO group than in the placebo group (p<.002, Kolmogorov-Smirnov test). The rHuEPO group was transfused with a total of 166 units of RBCs vs. 305 units of RBCs transfused in the placebo group. The final Hct concentration of the rHuEPO patients was significantly greater than the final Hct concentration of placebo patients (35.1+/-5.6 vs. 31.6+/-4.1; p<.01, respectively). A total of 45% of patients in the rHuEPO group received a blood transfusion between days 8 and 42 or died before study day 42 compared with 55% of patients in the placebo group (relative risk, 0.8; 95% confidence interval, 0.6, 1.1). There were no significant differences between the two groups either in mortality or in the frequency of adverse events. CONCLUSIONS: The administration of rHuEPO to critically ill patients is effective in raising their Hct concentrations and in reducing the total number of units of RBCs they require.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199911000-00004

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 351

Metadata

Authors
Corwin, H. L., Gettinger, A., Rodriguez, R. M., Pearl, R. G., Gubler, K. D., Enny, C., Colton, T., & Corwin, M. J.
Venue
Critical Care Medicine
Published
1999-11
Volume
27
Issue
11
Pages
2346-2350
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1970827178
Cited by
351
References
9
FWCI
9.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.