Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 476

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion

Pinto Lima, Alexandre, Beelen, Peter, Bakker, Jan·2002·Critical Care Medicine

Abstract

OBJECTIVE: Peripheral perfusion in critically ill patients frequently is assessed by use of clinical signs. Recently, the pulse oximetry signal has been suggested to reflect changes in peripheral perfusion. A peripheral perfusion index based on analysis of the pulse oximetry signal has been implemented in monitoring systems as an index of peripheral perfusion. No data on the variation of this index in the normal population are available, and clinical application of this variable in critically ill patients has not been reported. We therefore studied the variation of the peripheral perfusion index in healthy adults and related it to the central-to-toe temperature difference and capillary refill time in critically ill patients after changes in clinical signs of peripheral perfusion. DESIGN: Prospective study. SETTING: University-affiliated teaching hospital. PATIENTS: One hundred eight healthy adult volunteers and 37 adult critically ill patients. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Capillary refill time, peripheral perfusion index, and arterial oxygen saturation were measured in healthy adults (group 1). Capillary refill time, peripheral perfusion index, arterial oxygen saturation, central-to-toe temperature difference, and hemodynamic variables were measured in critically ill patients (group 2) during different peripheral perfusion profiles. Poor peripheral perfusion was defined as a capillary refill time >2 secs and central-to-toe temperature difference > or = 7 degrees C. Peripheral perfusion index and arterial oxygen saturation were measured by using the Philips Medical Systems Viridia/56S monitor. In group 1, measurements were made before and after a meal. In group 2, two measurements were made, with the second measurement taken when the peripheral perfusion profile had changed. A total of 216 measurements were carried out in group 1. The distribution of the peripheral perfusion index was skewed and values ranged from 0.3 to 10.0, median 1.4 (inner quartile range, 0.7-3.0). Seventy-four measurements were carried out in group 2. A significant correlation between the peripheral perfusion index and the core-to-toe temperature difference was found (R2=.52; p <.001). A cutoff peripheral perfusion index value of 1.4 (calculated by constructing a receiver operating characteristic curve) best reflected the presence of poor peripheral perfusion in critically ill patients. Changes in peripheral perfusion index and changes in core-to-toe temperature difference correlated significantly (R =.52, p <.001). CONCLUSIONS: The peripheral perfusion index distribution in the normal population is highly skewed. Changes in the peripheral perfusion index reflect changes in the core-to-toe temperature difference. Therefore, peripheral perfusion index measurements can be used to monitor peripheral perfusion in critically ill patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-200206000-00006

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 476

Metadata

Authors
Pinto Lima, A., Beelen, P., & Bakker, J.
Venue
Critical Care Medicine
Published
2002-06
Volume
30
Issue
6
Pages
1210-1213
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2135662590
Cited by
476
References
15
FWCI
2.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion. https://app.cochat.ai/papers/10.1097/00003246-200206000-00006
The paper
Pinto Lima, A., Beelen, P., & Bakker, J. (2002). Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion. Critical Care Medicine. https://doi.org/10.1097/00003246-200206000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.