The DOI matches its Crossref record.
The Contour Test of Loudness Perception
Abstract
OBJECTIVE: This article presents the underlying rationale, normative data, and reliability data for a test of loudness perception (the Contour Test) that was devised for use in clinical hearing aid fitting. The Contour Test yields data describing the sound level required for each of seven categories of loudness ranging from very soft to uncomfortably loud. DESIGN: Two experiments are described. Experiment 1 yielded norms for the test. The subjects were 23 male and 22 female normal-hearing listeners. Test stimuli included warble tones at six frequencies and broad band speech. Experiment 2 assessed the reliability of the test results. Ten hearing-impaired listeners responded to the test at two frequencies on two occasions separated by several days. Both experiments also evaluated the effect of using different stimulus increment sizes on the measured levels of loudness categories. RESULTS: Based on the data from experiment 1, norms for each category of each stimulus are reported in terms of mean level and typical between-subject variation in responses. Data are provided in HA-12 cm3 coupler levels as well as in hearing levels (dB HL). The shape of the loudness growth function for warble tones was somewhat different from that for speech. When data were expressed in HL, there were no differences in mean loudness category levels across warble tone test frequencies. Thus, test frequencies were combined and equations were generated to describe the upper and lower limits of typical normal performance for warble tone stimuli. These equations can be used to construct a template for clinical comparison of normative values to patient loudness growth curves. Experiment 2 provided information about the test-retest variability of data yielded by the Contour Test. Reliability appears to be similar to that of the few other category scaling tests described in the literature. Most test-retest differences were 6 dB or less. Although a moderate variation in test increment size did not significantly affect the loudness category levels for young normal-hearing listeners, levels corresponding to loudness categories were significantly higher when larger increments were used with elderly hearing-impaired listeners. CONCLUSIONS: Evidence from this and other research indicates that standardized measurement of loudness perception is an achievable goal for clinical practice. The Contour Test appears to offer a viable approach to clinical measurement of loudness perception: It has good patient acceptance and combines fairly rapid administration with acceptable reliability. Details of test procedures and scoring sheets for manual administration can be downloaded from the Internet at www.ausp.memphis.edu/harl. However, it is important to keep in mind that the application of loudness perception data for narrowband stimuli (such as warble tones) to hearing aid prescription is complicated by the need to account for the effects of loudness summation across bandwidth. There is a need for additional research to establish an empirical link between clinically measured loudness perception and optimal amplification characteristics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gu, J. W., Halpin, C. F., Nam, E.-C., Levine, R. A., & Melcher, J. R. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00226.2010 · Cited by 310
Treatments for decreased sound tolerance (hyperacusis and misophonia)
Jastreboff, M., & Jastreboff, P. (2014) · Seminars in Hearing · doi:10.1055/s-0034-1372527 · Cited by 245
Decreased Sound Tolerance and Tinnitus Retraining Therapy (TRT)
Jastreboff, M. M., & Jastreboff, P. J. (2002) · Australian and New Zealand Journal of Audiology · doi:10.1375/audi.24.2.74.31105 · Cited by 210
(2015) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-62630-1.00021-4 · Cited by 151
Sherlock, L. P., & Formby, C. (2005) · Journal of the American Academy of Audiology · doi:10.3766/jaaa.16.2.4 · Cited by 127
Metadata
- Authors
- Cox, R. M., Alexander, G. C., Taylor, I. M., & Gray, G. A.
- Venue
- Ear and Hearing
- Published
- 1997-10
- Volume
- 18
- Issue
- 5
- Pages
- 388-400
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W1991604810
- Cited by
- 183
- References
- 0
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Contour Test of Loudness Perception. https://app.cochat.ai/papers/10.1097/00003446-199710000-00004
- The paper
- Cox, R. M., Alexander, G. C., Taylor, I. M., & Gray, G. A. (1997). The Contour Test of Loudness Perception. Ear and Hearing. https://doi.org/10.1097/00003446-199710000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.