The Contour Test of Loudness Perception
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: This article presents the underlying rationale, normative data, and reliability data for a test of loudness perception (the Contour Test) that was devised for use in clinical hearing aid fitting. The Contour Test yields data describing the sound level required for each of seven categories of loudness ranging from very soft to uncomfortably loud. DESIGN: Two experiments are described. Experiment 1 yielded norms for the test. The subjects were 23 male and 22 female normal-hearing listeners. Test stimuli included warble tones at six frequencies and broad band speech. Experiment 2 assessed the reliability of the test results. Ten hearing-impaired listeners responded to the test at two frequencies on two occasions separated by several days. Both experiments also evaluated the effect of using different stimulus increment sizes on the measured levels of loudness categories. RESULTS: Based on the data from experiment 1, norms for each category of each stimulus are reported in terms of mean level and typical between-subject variation in responses. Data are provided in HA-12 cm3 coupler levels as well as in hearing levels (dB HL). The shape of the loudness growth function for warble tones was somewhat different from that for speech. When data were expressed in HL, there were no differences in mean loudness category levels across warble tone test frequencies. Thus, test frequencies were combined and equations were generated to describe the upper and lower limits of typical normal performance for warble tone stimuli. These equations can be used to construct a template for clinical comparison of normative values to patient loudness growth curves. Experiment 2 provided information about the test-retest variability of data yielded by the Contour Test. Reliability appears to be similar to that of the few other category scaling tests described in the literature. Most test-retest differences were 6 dB or less. Although a moderate variation in test increment size did not significantly affect the loudness category levels for young normal-hearing listeners, levels corresponding to loudness categories were significantly higher when larger increments were used with elderly hearing-impaired listeners. CONCLUSIONS: Evidence from this and other research indicates that standardized measurement of loudness perception is an achievable goal for clinical practice. The Contour Test appears to offer a viable approach to clinical measurement of loudness perception: It has good patient acceptance and combines fairly rapid administration with acceptable reliability. Details of test procedures and scoring sheets for manual administration can be downloaded from the Internet at www.ausp.memphis.edu/harl. However, it is important to keep in mind that the application of loudness perception data for narrowband stimuli (such as warble tones) to hearing aid prescription is complicated by the need to account for the effects of loudness summation across bandwidth. There is a need for additional research to establish an empirical link between clinically measured loudness perception and optimal amplification characteristics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Journal of experimental psychology: Human Perception and performance
(1987) · Journal of Sound and Vibration · doi:10.1016/0022-460x(87)90423-8 · Cited by 5,411
Preferred Method For Clinical Determination Of Pure-Tone Thresholds
Carhart, R., & Jerger, J. F. (1959) · Journal of Speech and Hearing Disorders · doi:10.1044/jshd.2404.330 · Cited by 1,114 · cited 1×
“This problem has many points of similarity with the effort to develop standardized methods for measurement of sensitivity thresholds, which culminated with an American National Standard (American National Standards Institute, 1978) recommending universal adoption of a variant of the procedure described by Carhart and…”
MethodJournal of the American Academy of Audiology
(2020) · Journal of the American Academy of Audiology · doi:10.1055/s-00046128 · Cited by 787
Critical Band Width in Loudness Summation
Zwicker, E., Flottorp, G., & Stevens, S. S. (1957) · The Journal of the Acoustical Society of America · doi:10.1121/1.1908963 · Cited by 740
Sequential effects in judgments of loudness.
Jesteadt, W., Luce, R. D., & Green, D. M. (1977) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037//0096-1523.3.1.92 · Cited by 186
Loudness growth in 1/2-octave bands (LGOB)—A procedure for the assessment of loudness
Allen, J. B., Hall, J. L., & Jeng, P. S. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399778 · Cited by 182
Sequential effects and memory in category judgments.
Ward, L. M., & Lockhead, G. R. (1970) · Journal of Experimental Psychology · doi:10.1037/h0028949 · Cited by 170
Description and Validation of an LDL Procedure Designed to Select SSPLSO
Hawkins, D. B., Walden, B. E., Montgomery, A., & Prosek, R. A. (1987) · Ear and Hearing · doi:10.1097/00003446-198706000-00006 · Cited by 110
The Connected Speech Test Version 3: Audiovisual Administration
Cox, R. M., Alexander, G. C., Gilrnore, C., & Pusakulich, K. M. (1989) · Ear and Hearing · doi:10.1097/00003446-198902000-00005 · Cited by 55
Self-citationTest-Retest Reliability of Loudness Scaling
Robinson, K., & Gatehouse, S. (1996) · Ear and Hearing · doi:10.1097/00003446-199604000-00005 · Cited by 51 · cited 1×
“These values are quite similar to the 3 dB to 7 dB reported by Robinson and Gatehouse (1996) for a somewhat more time-consuming category rating procedure.”
Method
Cited by
Gu, J. W., Halpin, C. F., Nam, E.-C., Levine, R. A., & Melcher, J. R. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00226.2010 · Cited by 310
Treatments for decreased sound tolerance (hyperacusis and misophonia)
Jastreboff, M., & Jastreboff, P. (2014) · Seminars in Hearing · doi:10.1055/s-0034-1372527 · Cited by 245
The search for noise-induced cochlear synaptopathy in humans: Mission impossible?
Bramhall, N., Beach, E. F., Epp, B., Le Prell, C. G., Lopez-Poveda, E. A., Plack, C. J., Schaette, R., Verhulst, S., & Canlon, B. (2019) · Hearing Research · doi:10.1016/j.heares.2019.02.016 · Cited by 217
“Alternatively, a measure of loudness growth, such as the Contour Test of Loudness Perception (Cox et al., 1997), or categorical loudness scaling (Brand and Hohmann, 2002), might be a better metric.”
Decreased Sound Tolerance and Tinnitus Retraining Therapy (TRT)
Jastreboff, M. M., & Jastreboff, P. J. (2002) · Australian and New Zealand Journal of Audiology · doi:10.1375/audi.24.2.74.31105 · Cited by 210
An adaptive procedure for categorical loudness scaling
Brand, T., & Hohmann, V. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1502902 · Cited by 176
Humes, L. E., Rogers, S. E., Quigley, T. M., Main, A. K., Kinney, D. L., & Herring, C. (2017) · American Journal of Audiology · doi:10.1044/2017_aja-16-0111 · Cited by 165
(2015) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-62630-1.00021-4 · Cited by 151
Sherlock, L. P., & Formby, C. (2005) · Journal of the American Academy of Audiology · doi:10.3766/jaaa.16.2.4 · Cited by 127
“The presentation level was incremented in 5 dB steps, as recommended for subjects with normalhearing sensitivity (Cox et al, 1997).”
BackgroundMethodResultInfluentialHawley, M., Sherlock, L., Gold, S., Payne, J., Brooks, R., Parton, J., Juneau, R., Desporte, E., Siegle, G., & Formby, C. (2015) · Seminars in Hearing · doi:10.1055/s-0035-1546958 · Cited by 41
Clinical and investigational tools for monitoring noise-induced hyperacusis
Jahn, K. N. (2022) · The Journal of the Acoustical Society of America · doi:10.1121/10.0012684 · Cited by 20
Hyperacusis diagnosis and management in the United States: clinical audiology practice patterns
Jahn, K. N., & Koach, C. E. (2023) · American Journal of Audiology · doi:10.1044/2023_aja-23-00118 · Cited by 15
Evaluation and Management of Misophonia Using a Hybrid Telecare Approach: A Case Report
Zitelli, L. (2021) · Seminars in Hearing · doi:10.1055/s-0041-1731693 · Cited by 4
Metadata
- Authors
- Cox, R. M., Alexander, G. C., Taylor, I. M., & Gray, G. A.
- Venue
- Ear and Hearing
- Published
- 1997-10
- Volume
- 18
- Issue
- 5
- Pages
- 388-400
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W1991604810
- Cited by
- 183
- References
- 17
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.