The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
From Laboratory to Clinic: A Large Scale Study of Distortion Product Otoacoustic Emissions in Ears with Normal Hearing and Ears with Hearing Loss
Abstract
OBJECTIVES: 1) To describe distortion product otoacoustic emission (DPOAE) measurements in large groups of subjects with normal hearing and with hearing loss, and to use these data to provide comprehensive descriptions of DPOAE test performance. 2) To describe the effects of primary frequency and audiometric threshold on the extent to which DPOAE measurements accurately identify auditory status. 3) To develop an approach that describes the probability that any measured response is coming from either a normal or an impaired ear. 4) To develop an approach for representing DPOAE data clinically. 5) To explore the relation between magnitude of hearing loss and DPOAE measurements. DESIGN: DPOAE measurements were made in 1267 ears of 806 subjects, using stimulus conditions that previously had been demonstrated to result in the greatest separation between normal and impaired ears (i.e., primary levels of 65/55 dB SPL for f1/f2; Stover et al., 1996). Subjects were recruited from local clinical populations and through local advertisements. All data were analyzed using clinical decision theory, including relative operating characteristic (ROC) curves and estimates of areas under these curves (Az). In addition, cumulative distributions were constructed of response properties from both normal and hearing-impaired ears. These cumulative distributions were used to select specific probabilities that measured responses were coming from either the normal or impaired distributions, and to develop an approach for describing clinical DPOAE data. RESULTS: For no conditions were the distributions of DPOAE responses from normal and impaired ears completely separated, meaning that optimal criterion values would still result in errors in identification of auditory status. Test performance, defined by Az, was best for mid and high frequencies and poorest for lower frequencies and for the highest frequency tested (8000 Hz). Performance was best when normal hearing was defined as audiometric thresholds between 20 and 30 dB HL, with poorer performance for more stringent or lax audiometric criteria. CONCLUSIONS: Within the limits related to the effects of primary frequency and audiometric criterion, it appears that DPOAE measurements can be used to accurately identify auditory status. An approach is described, using the present data set, that allows one to assign to any measured DPOAE value (DPOAE amplitudes, DPOAE/noise) the probability that the response is coming either from the distribution of normal or impaired responses. In addition, DPOAE/noise systematically decreases as hearing loss increases over the range of hearing losses from 0 to about 40 to 60 dB HL (depending on frequency), thus potentially enabling one to differentiate hearing losses over this range. For hearing losses greater than 50 to 60 dB HL, ears do not produce measurable DPOAEs and thus, no predictive relationship exists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058
Journal of Speech and Hearing Research
(2014) · Journal of Speech and Hearing Research · doi:10.1044/issn.0022-4685 · Cited by 902
Liberman, M. C., & Dodds, L. W. (1984) · Hearing Research · doi:10.1016/0378-5955(84)90025-x · Cited by 577
Evidence of mechanical nonlinearity and frequency selective wave amplification in the cochlea
Kemp, D. T. (1979) · Archives of Oto-Rhino-Laryngology · doi:10.1007/bf00455222 · Cited by 529
Outer Hair Cell Electromotility and Otoacoustic Emissions
Brownell, W. E. (1990) · Ear and Hearing · doi:10.1097/00003446-199004000-00003 · Cited by 525
Gaskill, S. A., & Brown, A. M. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399732 · Cited by 342
The Clinical Utility of Distortion-Product Otoacoustic Emissions
Lonsbury-Martin, B. L., & Martin, G. K. (1990) · Ear and Hearing · doi:10.1097/00003446-199004000-00009 · Cited by 233
Gorga, M. P., Neely, S. T., Bergman, B. M., Beauchaine, K. L., Kaminski, J. R., Peters, J., Schulte, L., & Jesteadt, W. (1993) · The Journal of the Acoustical Society of America · doi:10.1121/1.407348 · Cited by 191
Self-citationDistortion-Product Otoacoustic Emissions in Humans with High Frequency Sensorineural Hearing Loss
Harris, F. P. (1990) · Journal of Speech Language and Hearing Research · doi:10.1044/jshr.3303.594 · Cited by 79
Kimberley, B. P., Hernadi, I., Lee, A. M., & Brown, D. K. (1994) · Ear and Hearing · doi:10.1097/00003446-199406000-00001 · Cited by 69
Cited by
Auditory Neuropathy/Dys-synchrony and Its Perceptual Consequences
Rance, G. (2005) · Trends in Amplification · doi:10.1177/108471380500900102 · Cited by 282
An Exploratory Look at Pediatric Cochlear Implantation: Is Earliest Always Best?
Holt, R. F., & Svirsky, M. A. (2008) · Ear & Hearing · doi:10.1097/aud.0b013e31816c409f · Cited by 279
Schönfeldt-Lecuona, C., Cárdenas-Morales, L., Moreno-Aguirre, A., Dorn, K., Langguth, B., Brühl, A. B., Kammer, T., & Herwig, U. (2012) · Brain Topography · doi:10.1007/s10548-012-0218-1 · Cited by 15
Metadata
- Authors
- Gorga, M. P., Neely, S. T., Ohlrich, B., Hoover, B., Redner, J., & Peters, J.
- Venue
- Ear and Hearing
- Published
- 1997-12
- Volume
- 18
- Issue
- 6
- Pages
- 440-455
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2059943541
- Cited by
- 346
- References
- 10
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: From Laboratory to Clinic: A Large Scale Study of Distortion Product Otoacoustic Emissions in Ears with Normal Hearing and Ears with Hearing Loss. https://app.cochat.ai/papers/10.1097/00003446-199712000-00003
- The paper
- Gorga, M. P., Neely, S. T., Ohlrich, B., Hoover, B., Redner, J., & Peters, J. (1997). From Laboratory to Clinic: A Large Scale Study of Distortion Product Otoacoustic Emissions in Ears with Normal Hearing and Ears with Hearing Loss. Ear and Hearing. https://doi.org/10.1097/00003446-199712000-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.