Amplitude Mapping and Phoneme Recognition in Cochlear Implant Listeners

Zeng, Fan-Gang, Galvin, John J. · 1999 · Ear and Hearing

Abstract

OBJECTIVE: Speech and other environmental sounds must be compressed to accommodate the small electric dynamic range in cochlear implant listeners. The objective of this paper is to study whether and how amplitude compression and dynamic range reduction affect phoneme recognition in quiet and in noise for cochlear implant listeners. DESIGN: Four implant listeners using the Nucleus-22 SPEAK speech processor participated in this study. The amount of compression was varied by manipulating the Q-value in the SPEAK processor. The size of the dynamic range was systematically reduced by increasing the threshold level and decreasing the comfortable level in the processor. Both female- and male-talker vowel and consonant materials were used to evaluate speech recognition performance in quiet and in noise. Speech-spectrum-shaped noise was mixed with the speech signal and presented continuously to the speech processor through a direct electric connection. Signal to noise ratios were changed over a 30 to 40 dB range, within which phoneme recognition increased from chance to asymptotic performance. Phoneme recognition scores were obtained as the number of active electrodes was reduced from 20 to 10 to 4. For purposes of comparison, phoneme recognition data also were collected in four normal-hearing listeners under comparable laboratory conditions. RESULTS: In both quiet and noise, the amount of amplitude compression did not significantly affect phoneme recognition. The reduction of dynamic range marginally affected phoneme recognition in quiet, but significantly degraded phoneme recognition in noise. Generally, the 20- and 10-electrode processors produced similar performance, whereas the 4-electrode processor produced significantly poorer performance. Compared with normal-hearing listeners, cochlear-implant listeners required higher signal to noise ratios to achieve comparable recognition performance and produced significantly lower recognition scores at the same signal to noise ratios. CONCLUSIONS: The amount of amplitude compression does not significantly affect phoneme recognition, whereas reducing dynamic range significantly lowers phoneme recognition, particularly in noise and for vowels. Because the SPEAK processor extracts mostly spectral peaks, the present conclusions may not be applied to other types of processors extracting temporal envelope cues. The present results also suggest that more than four electrodes are required to optimize speech recognition in multiple-talker and noise conditions. A significant performance gap in speech recognition still remains between cochlear implant and normal-hearing listeners at the same signal to noise ratios. Improved cochlear implant designs and fitting procedures are required to narrow and, hopefully, close this performance gap.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003446-199902000-00006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 161

Metadata

Authors
Zeng, F.-G., & Galvin, J. J.
Venue
Ear and Hearing
Published
1999-02
Volume
20
Issue
1
Pages
60-74
ISSN
0196-0202 (ISSN-L)
OpenAlex
W2067976101
Cited by
161
References
1
FWCI
3.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Amplitude Mapping and Phoneme Recognition in Cochlear Implant Listeners. https://app.cochat.ai/papers/10.1097/00003446-199902000-00006
The paper
Zeng, F.-G., & Galvin, J. J. (1999). Amplitude Mapping and Phoneme Recognition in Cochlear Implant Listeners. Ear and Hearing. https://doi.org/10.1097/00003446-199902000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.