CoChat

An Improved Method of Reducing Stimulus Artifact in the Electrically Evoked Whole-Nerve Potential

Miller, Charles A., Abbas, Paul J., Brown, Carolyn J. · 2000 · Ear and Hearing
Cited by 122

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Recording a compound action potential in response to electrical stimulation requires attention to minimize contamination due to electrical stimulus artifact. In patients implanted with the Nucleus 24 device, the electrically evoked whole-nerve potential (EAP) is recorded using a neural response telemetry (NRT) system. This system employs a forward-masking technique that greatly reduces stimulus artifact. However, theoretical considerations and experimental animal data suggest that the technique may distort the acquired EAP waveform under some situations. We proposed and evaluated a modification to the forward-masking technique that addresses this concern, particularly during collection of refractory recovery data. DESIGN: We first examined neural responses of the electrically stimulated auditory nerve using cat preparations. Through single-fiber recordings from cats, we demonstrated underlying physiological limitations likely encountered with the "standard" forward masking technique. We then recorded feline EAP waveforms using both the standard technique and our proposed, modified, technique. Finally, we collected EAP data from human cochlear implant patients using both artifact reduction methods. These comparisons allowed us to evaluate the effectiveness of our modification. RESULTS: The cat EAP data demonstrated that the standard forward-masking technique currently in use in the Nucleus NRT system can distort the EAP waveform when the nerve is partially refractory. In the cat, this distortion resulted in forward-masking recovery curves with artifactually prolonged recovery times and inaccurate latency trends. Similar effects were observed in the comparison of human recovery curves obtained using both the standard and modified techniques. In some cases, the modified technique produced EAP waveforms with more clearly defined peaks than were obtainable with the standard method. CONCLUSIONS: Consideration should be given to implementing our modified forward-masking artifact reduction scheme, because it introduces less distortion of the EAP waveform and accordingly provides for more accurate assessment of the refractory properties of the electrically stimulated nerve.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003446-200008000-00003

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 122

Metadata

Authors
Miller, C. A., Abbas, P. J., & Brown, C. J.
Venue
Ear and Hearing
Published
2000-08
Volume
21
Issue
4
Pages
280-290
ISSN
0196-0202 (ISSN-L)
OpenAlex
W2008320728
Cited by
122
References
0
FWCI
0.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Improved Method of Reducing Stimulus Artifact in the Electrically Evoked Whole-Nerve Potential. https://app.cochat.ai/papers/10.1097/00003446-200008000-00003
The paper
Miller, C. A., Abbas, P. J., & Brown, C. J. (2000). An Improved Method of Reducing Stimulus Artifact in the Electrically Evoked Whole-Nerve Potential. Ear and Hearing. https://doi.org/10.1097/00003446-200008000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.