An Improved Method of Reducing Stimulus Artifact in the Electrically Evoked Whole-Nerve Potential
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Recording a compound action potential in response to electrical stimulation requires attention to minimize contamination due to electrical stimulus artifact. In patients implanted with the Nucleus 24 device, the electrically evoked whole-nerve potential (EAP) is recorded using a neural response telemetry (NRT) system. This system employs a forward-masking technique that greatly reduces stimulus artifact. However, theoretical considerations and experimental animal data suggest that the technique may distort the acquired EAP waveform under some situations. We proposed and evaluated a modification to the forward-masking technique that addresses this concern, particularly during collection of refractory recovery data. DESIGN: We first examined neural responses of the electrically stimulated auditory nerve using cat preparations. Through single-fiber recordings from cats, we demonstrated underlying physiological limitations likely encountered with the "standard" forward masking technique. We then recorded feline EAP waveforms using both the standard technique and our proposed, modified, technique. Finally, we collected EAP data from human cochlear implant patients using both artifact reduction methods. These comparisons allowed us to evaluate the effectiveness of our modification. RESULTS: The cat EAP data demonstrated that the standard forward-masking technique currently in use in the Nucleus NRT system can distort the EAP waveform when the nerve is partially refractory. In the cat, this distortion resulted in forward-masking recovery curves with artifactually prolonged recovery times and inaccurate latency trends. Similar effects were observed in the comparison of human recovery curves obtained using both the standard and modified techniques. In some cases, the modified technique produced EAP waveforms with more clearly defined peaks than were obtainable with the standard method. CONCLUSIONS: Consideration should be given to implementing our modified forward-masking artifact reduction scheme, because it introduces less distortion of the EAP waveform and accordingly provides for more accurate assessment of the refractory properties of the electrically stimulated nerve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“13 shows three techniques used to remove the electric artifacts [109], [110].”
BackgroundMethodApplication of infrared light for in vivo neural stimulation
Wells, J., Kao, C., Jansen, E. D., Konrad, P., & Mahadevan-Jansen, A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2121772 · Cited by 291
Cohen, L. T., Richardson, L. M., Saunders, E., & Cowan, R. S. C. (2003) · Hearing Research · doi:10.1016/s0378-5955(03)00096-0 · Cited by 220
Minimization of cochlear implant stimulus artifact in cortical auditory evoked potentials
Gilley, P. M., Sharma, A., Dorman, M., Finley, C. C., Panch, A. S., & Martin, K. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.018 · Cited by 189
“This approach would also require temporal synchronization of the external acoustic stimulus, the pulse train delivered by the processor, and the sampling clock of the recording system (Miller et al., 2000; van den Honert and Stypulkowski , 1986).”
BackgroundCochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation
Zhu, Z., Tang, Q., Zeng, F.-G., Guan, T., & Ye, D. (2012) · Hearing Research · doi:10.1016/j.heares.2011.11.005 · Cited by 115
“On the other hand, a forward-masking subtraction method to measure electrical compound action potentials (ECAP, see Abbas et al., 2004; Miller et al., 2000) has been used to characterize the physiological spatial masking curve, a counterpart of the psychophysical spatial tuning curves (Cohen et…”
BackgroundMethod
Metadata
- Authors
- Miller, C. A., Abbas, P. J., & Brown, C. J.
- Venue
- Ear and Hearing
- Published
- 2000-08
- Volume
- 21
- Issue
- 4
- Pages
- 280-290
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2008320728
- Cited by
- 122
- References
- 0
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Improved Method of Reducing Stimulus Artifact in the Electrically Evoked Whole-Nerve Potential. https://app.cochat.ai/papers/10.1097/00003446-200008000-00003
- The paper
- Miller, C. A., Abbas, P. J., & Brown, C. J. (2000). An Improved Method of Reducing Stimulus Artifact in the Electrically Evoked Whole-Nerve Potential. Ear and Hearing. https://doi.org/10.1097/00003446-200008000-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.