Speech Recognition in Noise for Cochlear Implantees with a Two-Microphone Monaural Adaptive Noise Reduction System
The DOI matches its Crossref record.
Abstract
OBJECTIVE: In this study the performance of a noise reduction strategy applied to cochlear implants is evaluated. The noise reduction strategy is based on a 2-channel adaptive filtering strategy using two microphones in a single behind-the-ear hearing aid. DESIGN: Four adult LAURA cochlear implant users (Peeters et al., 1993) took part in the experiments. The tests included identification of monosyllabic CVC (consonant-vowel-consonant) words and measurements of the speech reception threshold (SRT) of lists of numbers, in background noise presented at 90 degrees relative to the 0 degrees frontal direction of the speech. Percent correct phoneme scores for the CVC words at signal to noise ratios (SNRs) of -5, 0, and +5 dB in steady speech-weighted noise at 60 dB SPL and SRTs for numbers in speech-weighted steady and nonsteady ICRA noise were both obtained in conditions with and without the noise reduction pre-processing. Physical SNR improvements of the noise reduction system are evaluated as well, as a function of the direction of the noise source. RESULTS: Highly significant improvements in speech understanding, corresponding on average to an SNR improvement of about 10 dB, were observed with this 2-channel adaptive filtering noise reduction strategy using both types of speech-noise test materials. These perceptual evaluations agree with physical evaluations and simulations of this noise reduction strategy. Taken together, these data demonstrate that cochlear implantees may increase their speech intelligibility in noisy environments with the use of multimicrophone noise reduction systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Importantly, the effort required to listen to speech in noise is a commonly reported complaint in people with hearing impairment (Arlinger et al., 2009; Hawkins & Yacullo, 1984; Wouters & Berghe, 2001) that is not currently captured in standard clinical speech tests.”
From Objective Assessment of Listening Effort: Coregistration of Pupillometry and EEG (2017) · cites this paper as Wouters & Berghe, 2001
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 30
- Byrne, 1994, The Journal of the Acoustical Society of America, 96, 2108, 10.1121/1.410152 · DOI
- Dowell, 1987, Acta Oto-laryngologica, 104, 439, 10.3109/00016488709128272 · doi:10.3109/00016488709128272
- Festen, 1990, The Journal of the Acoustical Society of America, 88, 1725, 10.1121/1.400247 · DOI · Paper page
- Fu, 1998, The Journal of the Acoustical Society of America, 104, 3586, 10.1121/1.423941 · DOI
- Hawkins, 1984, Journal of Speech Hearing Disorders, 49, 278, 10.1044/jshd.4903.278 · DOI · Paper page
- Helms, 1997, Otorhinolaryngology, 59, 23
- Hochberg, 1992, Ear Hearing, 13, 263, 10.1097/00003446-199208000-00008 · doi:10.1097/00003446-199208000-00008
- Holden, 1995, American Journal of Audiology, 4, 55, 10.1044/1059-0889.0403.55 · doi:10.1044/1059-0889.0403.55
- Kiefer, 1996, ORL Journal for Oto-rhino-laryngology its Related Specialties, 58, 127, 10.1159/000276812 · doi:10.1159/000276812
- Killion, 1997, British Journal of Audiology, 31, 141, 10.3109/03005364000000016 · DOI
- McDermott, 1992, The Journal of the Acoustical Society of America, 91, 3367, 10.1121/1.402826 · DOI · Paper page
- McKay, 1993, Ear Hearing, 14, 350, 10.1097/00003446-199310000-00006 · doi:10.1097/00003446-199310000-00006
- Parkinson, 1998, Journal of Speech Language Hearing Research, 41, 1073, 10.1044/jslhr.4105.1073 · DOI
- Peeters, 1993, Progress in Brain Research, 97, 283, 10.1016/S0079-6123(08)62288-8 · DOI
- Peters, 1998, Journal of Speech Language Hearing Research, 103, 577
- Plomp, 1986, Journal of Speech Hearing Research, 29, 146, 10.1044/jshr.2902.146 · DOI
- Plomp, 1979, Audiology, 18, 43, 10.3109/00206097909072618 · DOI · Paper page
- Ricketts, 2000, Ear Hearing, 21, 194, 10.1097/00003446-200006000-00002 · doi:10.1097/00003446-200006000-00002
- Skinner, 1996, Ear Hearing, 17, 182, 10.1097/00003446-199606000-00002 · doi:10.1097/00003446-199606000-00002
- Skinner, 1997, Journal of Speech Language Hearing Research, 101, 3766
- Stone, 1999, Ear Hearing, 20, 182, 10.1097/00003446-199906000-00002 · DOI · Paper page
- Tyler, 1992, Journal of Speech Language Hearing Research, 92, 3068
- Van Hoesel, 1995, The Journal of the Acoustical Society of America, 97, 2498, 10.1121/1.411970 · doi:10.1121/1.411970
- van Wieringen, 1999, Ear Hearing, 20, 89, 10.1097/00003446-199904000-00001 · doi:10.1097/00003446-199904000-00001
- Vanden Berghe, 1998, Journal of the Acoustical Society of America, 103, 3621, 10.1121/1.423066 · doi:10.1121/1.423066
- Versfeld, 1999, The Journal of the Acoustical Society of America, 107, 1671, 10.1121/1.428451 · DOI · Paper page
- Weiss, 1993, Journal of Rehabilitation Research Development, 30, 117
- Wilson, 1991, Nature, 352, 236, 10.1038/352236a0 · DOI · Paper page
- Wouters, 1994, Logopedie, 7, 28
- Wouters, 1999, Audiology, 38, 91, 10.3109/00206099909073008 · doi:10.3109/00206099909073008
Cited by
Speech Processing in Vocoder-Centric Cochlear Implants
Loizou, P. C. (2006) · Advances in Oto-Rhino-Laryngology · doi:10.1159/000094648 · Cited by 216
“[93] Wouters J, Berghe J: Speech recognition in noise for cochlear implantees with a two-microphone monaural adaptive noise reduction system.”
BackgroundMethodThe Development of the Nucleus® Freedom™ Cochlear Implant System
Patrick, J. F., Busby, P. A., & Gibson, P. J. (2006) · Trends in Amplification · doi:10.1177/1084713806296386 · Cited by 196
Spriet, A., Van Deun, L., Eftaxiadis, K., Laneau, J., Moonen, M., van Dijk, B., van Wieringen, A., & Wouters, J. (2007) · Ear & Hearing · doi:10.1097/01.aud.0000252470.54246.54 · Cited by 161
Self-citationObjective Assessment of Listening Effort: Coregistration of Pupillometry and EEG
Miles, K., McMahon, C., Boisvert, I., Ibrahim, R., de Lissa, P., Graham, P., & Lyxell, B. (2017) · Trends in Hearing · doi:10.1177/2331216517706396 · Cited by 128
“Importantly, the effort required to listen to speech in noise is a commonly reported complaint in people with hearing impairment (Arlinger et al., 2009; Hawkins & Yacullo, 1984; Wouters & Berghe, 2001) that is not currently captured in standard clinical speech tests.”
Wang, N. Y.-H., Wang, H.-L. S., Wang, T.-W., Fu, S.-W., Lu, X., Wang, H.-M., & Tsao, Y. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3042655 · Cited by 24
“On the other hand, the applicability of multi-microphone approaches is restricted to acoustic situation where the target and noise are spatially separated, and its efficacy decreases in reverberant environments [31].”
Background
Metadata
- Authors
- Wouters, J., & Vanden Berghe, J.
- Venue
- Ear and Hearing
- Published
- 2001-10
- Volume
- 22
- Issue
- 5
- Pages
- 420-430
- ISSN
- 0196-0202
- Cited by
- 104
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.