The DOI matches its Crossref record.
Speech Processing in Vocoder-Centric Cochlear Implants
Abstract
The principles of the most recent cochlear implant processors are similar to that of the channel vocoder, originally used for transmitting speech over telephone lines with much less bandwidth than that required for transmitting the unprocessed speech signal. An overview of the various vocoder-centric processing strategies proposed for cochlear implants since the late 1990s is provided including the strategies used in different commercially available implant processors. Special emphasis is placed on reviewing the strategies designed to enhance pitch information for potentially better music perception. The various noise suppression strategies proposed over the years based on multi-microphone and single-microphone inputs are also described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blamey, P., Artieres, F., Başkent, D., Bergeron, F., Beynon, A., Burke, E., Dillier, N., Dowell, R., Fraysse, B., Gallégo, S., et al. (2013) · Audiology and Neurotology · doi:10.1159/000343189 · Cited by 676
Identification of Minimal Pairs of Japanese Pitch Accent in Noise-Vocoded Speech
Sugiyama, Y. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2022.887761 · Cited by 4
Metadata
- Authors
- Loizou, P. C.
- Venue
- Advances in Oto-Rhino-Laryngology
- Publisher
- S. KARGER AG
- Published
- 2006
- Volume
- 64
- Pages
- 109-143
- ISSN
- 0065-3071 (ISSN-L)
- 1662-2847
- OpenAlex
- W2106244103
- Cited by
- 216
- References
- 0
- FWCI
- 14.06
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Speech Processing in Vocoder-Centric Cochlear Implants. https://app.cochat.ai/papers/10.1159/000094648
- The paper
- Loizou, P. C. (2006). Speech Processing in Vocoder-Centric Cochlear Implants. Advances in Oto-Rhino-Laryngology. https://doi.org/10.1159/000094648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.