Volumetric Determination of Placental and Uterine Growth Relationships from B-Mode Ultrasound by Serial Area???Volume Determinations
Abstract
Serial area-volume determinations may be made from B-mode ultrasonography. Multiple sonographic sections are taken through a structure of interest. The area of the structure of interest is determined on each sonographic section by a form of planimetry and multiplied by the step-interval to obtain the volume of the structure of interest between sonographic sections. The total volume of the structure of interest is the sum of the individual volumes. The volume is computed from both transverse and longitudinal images and an average obtained for improved accuracy. Total intrauterine volume and placental volume were determined by the serial area-volume method in 63 normal patients and the results were analyzed. Placental and total intrauterine volumes were also determined for five cases of intrauterine growth retardation. Although there is some error in the serial area-volume method, the initial evaluation of five cases with intrauterine growth retardation suggests a greater precision and accuracy than volume estimates based on prolate ellipsoid geometry. Placental volume may provide an acceptable parameter to screen for intrauterine growth retardation.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
It was suggested as early as 1981 that PlVol measured with B-mode ultrasound could be used to screen for growth restriction.
“First trimester placental volume (PlVol) has long been known to correlate with birth weight at term (7-9), and it was suggested as early as 1981 that PlVol measured with B-mode ultrasound could be used to screen for growth restriction (10).”
From Fully automated, real-time 3D ultrasound segmentation to estimate first trimester placental volume using deep learning (2018) · cites this paper as [10]
Cited by
Sorted by citations
Abduljalil, K., Furness, P., Johnson, T. N., Rostami-Hodjegan, A., & Soltani, H. (2012) · Clinical Pharmacokinetics · doi:10.2165/11597440-000000000-00000 · Cited by 371 · see citing works
Jackson, M., Gott, P. J., Lye, S. J., Ritchie, J. W. K., & Clapp, J. F. (1995) · Placenta · doi:10.1016/0143-4004(95)90007-1 · Cited by 123 · see citing works
Dallmann, A., Ince, I., Meyer, M. C., Willmann, S., Eißing, T., & Hempel, G. (2017) · Clinical Pharmacokinetics · doi:10.1007/s40262-017-0539-z · Cited by 121 · see citing works
Looney, P., Stevenson, G. N., Nicolaides, K. H., Plasencia, W., Molloholli, M., Natsis, S., & Collins, S. L. (2018) · JCI Insight · doi:10.1172/jci.insight.120178 · Cited by 111 · see citing works
“First trimester placental volume (PlVol) has long been known to correlate with birth weight at term (7–9), and it was suggested as early as 1981 that PlVol measured with B-mode ultrasound could be used to screen for growth restriction (10).”
BackgroundMethodEffect of recreational exercise on midtrimester placental growth
Clapp, J. F., & Rizk, K. H. (1992) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(92)91730-x · Cited by 80 · see citing works
Ontogenic changes in the nutritive function of the placenta
Schneider, H. (1996) · Placenta · doi:10.1016/s0143-4004(05)80639-3 · Cited by 79 · see citing works
Second-trimester placental volume measurement by ultrasound: Prediction of fetal outcome
Wolf, H., Oosting, H., & Treffers, P. E. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90102-6 · Cited by 74 · see citing works
Sonographic determination of renal volumes in normal neonates
Holloway, H., Jones, T. B., Robinson, A. E., et al. (1983) · Pediatric Radiology · doi:10.1007/bf00973158 · Cited by 49 · see citing works
“The serial area-volume method of volume determination has been described previously [ 6 ].”
MethodSelf-citationGeirsson, R. T., Christie, A. D., & Patel, N. B. (1982) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870100707 · Cited by 38 · see citing works
Second-Trimester Placental Volumes Predict Birth Weight at Term
Clapp, J. F., Rizk, K. H., Appleby-Wineberg, S. K., & Crass, J. R. (1995) · Journal of the Society for Gynecologic Investigation · doi:10.1177/107155769500200104 · Cited by 42 · see citing works
Volume and vascularity: Using ultrasound to unlock the secrets of the first trimester placenta
Mathewlynn, S., & Collins, S. L. (2019) · Placenta · doi:10.1016/j.placenta.2019.06.379 · Cited by 30 · see citing works
Measurement of placental volume with real‐time ultrasound in mid‐pregnancy
Howe, D., Wheeler, T., & Perring, S. (1994) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870220203 · Cited by 28 · see citing works
Placental volume measurement by ultrasonography: Evaluation of the method
Wolf, H., Oosting, H., & Treffers, P. E. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(87)90141-4 · Cited by 26 · see citing works
Geirsson, R. T. (1986) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016348609156385 · Cited by 12 · see citing works
Geirsson, R. T., Patel, N. B., & Christie, A. D. (1985) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1985.tb03072.x · Cited by 10 · see citing works
Fetal biometry and intrauterine growth retardation. Current concepts.
Neumann, C. H., & Carroll, B. A. (1984) · PubMed · Cited by 7 · see citing works
Gleason, R. L., & Sedaghati, F. (2022) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-021-01555-0 · Cited by 6 · see citing works
“The cross sections of the uterus in the coronal and sagittal planes and geometric parameters for the uterine wall throughout gestation are consistent typical reported values (Jones et al. 1981; Edgar 1910).”
ResultAlyafei, F., Soliman, A. T., Sanctis, V. D., Qubasi, M. A., Olukade, T. O., Alaaraj, N., Hamed, N., Ahmed, S., Soliman, N. A., & Yassin, D. K. (2023) · PubMed Central · doi:10.23750/abm.v94i4.14434 · Cited by 1 · see citing works
XXII Scandinavian Congress of Obstetrics and Gynecology
Nilsson, C. G., & Backas, N.-E. (1983) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016348309156264
Volumetric Determination of Breast and Mammary Gland Using Ultrasono-tomography
Sugino, H. (1989) · Juntendō Igaku/Juntendo igaku · doi:10.14789/pjmj.34.499
Zambella, E., Inversetti, A., Pivato, C. A., Cristodoro, M., Stefanini, G. G., & Simone, N. D. (2026) · European Heart Journal - Quality of Care and Clinical Outcomes · doi:10.1093/ehjqcco/qcag020 · Cited by 1 · see citing works
- Authors
- JONES, T. B., PRICE, R. R., & GIBBS, S. J.
- Affiliations
- Vanderbilt University (US)
- ORCID
- GIBBS, S JULIAN
- Venue
- Investigative Radiology
- Published
- 1981-03
- Volume
- 16
- Issue
- 2
- Pages
- 101-106
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2028121530
- Cited by
- 21
- References
- 0
- Citations by year
- 2026: 1 · 2023: 1 · 2022: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2012: 1
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Investigative Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
- Keywords
- placental volume, uterine volume, fetal growth restriction, B-mode ultrasound, planimetry
- MeSH terms
- Female, Fetal Growth Retardation, Humans, Placenta, Pregnancy, Ultrasonography, Uterus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review