The DOI matches its Crossref record.
Computerized Detection of Pulmonary Nodules in Computed Tomography Images
Abstract
RATIONALE AND OBJECTIVES: Interpretation of computed tomographic (CT) scans of the lungs is a time-consuming task that involves visual correlation of possible nodules in one section with those in contiguous sections to distinguish actual nodules from blood vessels. Thus, the authors are developing automated methods to detect nodules on CT images of the thorax. METHODS: The computerized technique uses various computer-vision techniques and a priori information of the morphologic characteristics of pulmonary nodules. In each section, the external thoracic wall and lung boundaries are detected, and the features within the lung boundaries are subjected to gray-level thresholding operations. By analyzing the relationships between features arising at different threshold levels with respect to their shape, size, and location, each feature is assigned a likelihood of being a nodule or a vessel. Features in adjacent sections are compared to resolve ambiguous features. Detected nodule candidates are displayed in three dimensions within the lung. RESULTS: The system provided a sensitivity of 94% for nodule detection and an average of 1.25 false-positive results per case. CONCLUSIONS: Continued development of an automated method for detecting pulmonary nodules in CT scans is expected to aid radiologists in the task of locating nodules in three dimensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932744 · Cited by 457
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Quantifying tumour heterogeneity with CT
Ganeshan, B., & Miles, K. A. (2013) · Cancer Imaging · doi:10.1102/1470-7330.2013.0015 · Cited by 395
Lung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
Armato III, S. G., McLennan, G., McNitt-Gray, M. F., Meyer, C. R., Yankelevitz, D., Aberle, D. R., Henschke, C. I., Hoffman, E. A., Kazerooni, E. A., MacMahon, H., et al. (2004) · Radiology · doi:10.1148/radiol.2323032035 · Cited by 380
Self-citationTissue classification based on 3D local intensity structures for volume rendering
Sato, Y., Westin, C., Bhalerao, A., Nakajima, S., Shiraga, N., Tamura, S., & Kikinis, R. (2000) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.856997 · Cited by 338
Metadata
- Authors
- GIGER, M. L., BAE, K. T., & MacMAHON, H.
- Venue
- Investigative Radiology
- Published
- 1994-04
- Volume
- 29
- Issue
- 4
- Pages
- 459-465
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2095003563
- Cited by
- 200
- References
- 0
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computerized Detection of Pulmonary Nodules in Computed Tomography Images. https://app.cochat.ai/papers/10.1097/00004424-199404000-00013
- The paper
- GIGER, M. L., BAE, K. T., & MacMAHON, H. (1994). Computerized Detection of Pulmonary Nodules in Computed Tomography Images. Investigative Radiology. https://doi.org/10.1097/00004424-199404000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.