Abstract
RATIONALE AND OBJECTIVES: New targeted microbubbles directed to the GPIIb IIIa receptor have been developed. The objective was to determine whether targeting microbubbles to clots would enhance ultrasound imaging. Systematic studies were designed to determine whether in vitro methodology is an acceptable predictor of in vivo efficacy. MATERIALS AND METHODS: Bioconjugate ligands were inserted into lipid-coated membranes of perfluorocarbon gas microbubbles and binding studies performed on activated platelets immobilized on cell culture plates. Targeted microbubble binding to clots in a flow through chamber was also assessed. Finally, microbubble binding studies on arteriolar and venular clots in a mouse cremasteric muscle model were conducted. RESULTS: Binding studies on platelet-immobilized plates demonstrated an affinity for targeted microbubbles versus untargeted microbubbles. Semiquantitative light obscuration techniques helped to measure extent of targeted microbubble binding. Targeted microbubbles similarly bound to platelet clots in the flow model. Finally, studies in the mouse model confirmed binding of targeted microbubbles in both venules and arterioles. CONCLUSION: The use of receptor selective targeted microbubbles improved binding to vascular thrombi in both in vitro and in vivo settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Novel Site-Targeted Ultrasonic Contrast Agent With Broad Biomedical Application
Lanza, G. M., Wallace, K. D., Scott, M. J., Cacheris, W. P., Abendschein, D. R., Christy, D. H., Sharkey, A. M., Miller, J. G., Gaffney, P. J., & Wickline, S. A. (1996) · Circulation · doi:10.1161/01.cir.94.12.3334 · Cited by 406
Cited by
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Microbubbles and ultrasound: from diagnosis to therapy
DIJKMANS, P., JUFFERMANS, L., MUSTERS, R., VANWAMEL, A., TENCATE, F., VANGILST, W., VISSER, C., DEJONG, N., & KAMP, O. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.02.001 · Cited by 420
Metadata
- Authors
- SCHUMANN, P. A., CHRISTIANSEN, J. P., QUIGLEY, R. M., MCCREERY, T. P., SWEITZER, R. H., UNGER, E. C., LINDNER, J. R., & MATSUNAGA, T. O.
- Venue
- Investigative Radiology
- Published
- 2002-11
- Volume
- 37
- Issue
- 11
- Pages
- 587-593
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2067879263
- Cited by
- 211
- References
- 1
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Targeted-Microbubble Binding Selectively to GPIIb IIIa Receptors of Platelet Thrombi. https://app.cochat.ai/papers/10.1097/00004424-200211000-00001
- The paper
- SCHUMANN, P. A., CHRISTIANSEN, J. P., QUIGLEY, R. M., MCCREERY, T. P., SWEITZER, R. H., UNGER, E. C., LINDNER, J. R., & MATSUNAGA, T. O. (2002). Targeted-Microbubble Binding Selectively to GPIIb IIIa Receptors of Platelet Thrombi. Investigative Radiology. https://doi.org/10.1097/00004424-200211000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.