Cited by 406Ultrasound and Hyperthermia ApplicationsPhotoacoustic and Ultrasonic ImagingUltrasound Imaging and Elastography

A Novel Site-Targeted Ultrasonic Contrast Agent With Broad Biomedical Application

Lanza, Gregory M., Wallace, Kirk D., Scott, Michael J., Cacheris, William P., Abendschein, Dana R., Christy, Donald H., Sharkey, Angela M., Miller, James G. +2 more·1996·Circulation

Abstract

Background In this work, we report a novel targetable ultrasonic contrast agent with the potential to noninvasively define and localize myriad pathological tissues for diagnosis or therapy. The agent is a biotinylated, lipid-coated, perfluorocarbon emulsion that has low inherent echogenicity unless bound to a surface or itself. Methods and Results In study 1, emulsions with and without biotin were suspended in buffered saline and imaged with a 7.5-MHz linear-array transducer. Neither emulsion manifested significant ultrasonic backscatter until avidin was added. Avidin-induced aggregation produced a marked enhancement in backscatter from the biotinylated but not from the control emulsion. In study 2, porcine fibrin clots in vitro were pretargeted with biotinylated antifibrin monoclonal antibodies and then exposed to avidin and then to biotinylated or control perfluorocarbon emulsions. The basal acoustic reflectivity of clots imaged with a 7.5-MHz linear-array transducer was uniformly low and was increased substantially by exposure to the targeted biotinylated emulsion. In study 3, partially occlusive arterial thrombi were created in dogs and then exposed to antifibrin antibodies and avidin in situ. Biotinylated or control emulsion was administered either in situ or systemically. At baseline, all thrombi were undetectable with a 7.5-MHz linear-array transducer. Thrombi exposed to antifibrin-targeted contrast exhibited increased echogenicity ( P <.05); control thrombi remained acoustically undetectable. Conclusions These data provide the first in vivo demonstration of a site-specific ultrasonic contrast agent and have potential for improved sensitivity and specificity for noninvasive diagnosis of thrombi and other pathological diseases.

Integrity signals

Registry

Crossref · 10.1161/01.cir.94.12.3334

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lanza, G. M., Wallace, K. D., Scott, M. J., Cacheris, W. P., Abendschein, D. R., Christy, D. H., Sharkey, A. M., Miller, J. G., Gaffney, P. J., & Wickline, S. A.
Affiliations
Barnes-Jewish Hospital (US)
Venue
Circulation
Published
1996-12-15
Volume
94
Issue
12
Pages
3334-3340
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2037253046
Cited by
406
References
25
Citations by year
2026: 2 · 2025: 4 · 2024: 4 · 2023: 7 · 2022: 1 · 2021: 8 · 2020: 3 · 2019: 8 · 2018: 6 · 2017: 5 · 2016: 7 · 2015: 7 · 2014: 16 · 2013: 19 · 2012: 17
FWCI
6.17
Type
journal article
Language
en
Open access
closed
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r01hl042950-17)
  • National Heart, Lung, and Blood Institute (HL 42950)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
Keywords
ultrasound contrast agents, targeted imaging, avidin-biotin binding, perfluorocarbon emulsions, fibrin clot, thrombus localization, non-invasive diagnosis
MeSH terms
Animals, Antibodies, Monoclonal, Avidin, Biotin, Contrast Media, Dogs, Emulsions, Femoral Artery, Fibrin, Fluorocarbons, Phosphatidylethanolamines, Scattering, Radiation, Swine, Thrombosis, Ultrasonography, Ultrasonic Therapy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review