The DOI matches its Crossref record.
Absolute Cerebral Blood Flow and Blood Volume Measured by Magnetic Resonance Imaging Bolus Tracking: Comparison with Positron Emission Tomography Values
Open accessAbstract
The authors determined cerebral blood flow (CBF) with magnetic resonance imaging (MRI) of contrast agent bolus passage and compared the results with those obtained by O-15 labeled water (H 215 O) and positron emission tomography (PET). Six pigs were examined by MRI and PET under normo- and hypercapnic conditions. After dose normalization and introduction of an empirical constant Φ Gd, absolute regional CBF was calculated from MRI. The spatial resolution and the signal-to-noise ratio of CBF measurements by MRI were better than by the H 215 O-PET protocol. Magnetic resonance imaging cerebral blood volume (CBV) estimates obtained using this normalization constant correlated well with values obtained by O-15 labeled carbonmonooxide (C 15 O) PET. However, PET CBV values were approximately 2.5 times larger than absolute MRI CBV values, supporting the hypothesized sensitivity of MRI to small vessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Diffusion- and Perfusion-Weighted MRI: The DWI/PWI Mismatch Region in Acute Stroke
Neumann-Haefelin, T., Wittsack, H.-J., Wenserski, F., Siebler, M., Seitz, R. J., Mödder, U., & Freund, H.-J. (1999) · Stroke · doi:10.1161/01.str.30.8.1591 · Cited by 568
Markus, H. (2001) · Brain · doi:10.1093/brain/124.3.457 · Cited by 542
Functional magnetic resonance imaging based on changes in vascular space occupancy
Lu, H., Golay, X., Pekar, J. J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10519 · Cited by 463
Metadata
- Authors
- Østergaard, L., Smith, D. F., Vestergaard-Poulsen, P., Hansen, S., Gee, A. D., Gjedde, A., & Gyldensted, C.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 1998-04
- Volume
- 18
- Issue
- 4
- Pages
- 425-432
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2020383693
- Cited by
- 202
- References
- 0
- FWCI
- 19.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Absolute Cerebral Blood Flow and Blood Volume Measured by Magnetic Resonance Imaging Bolus Tracking: Comparison with Positron Emission Tomography Values. https://app.cochat.ai/papers/10.1097/00004647-199804000-00011
- The paper
- Østergaard, L., Smith, D. F., Vestergaard-Poulsen, P., Hansen, S., Gee, A. D., Gjedde, A., & Gyldensted, C. (1998). Absolute Cerebral Blood Flow and Blood Volume Measured by Magnetic Resonance Imaging Bolus Tracking: Comparison with Positron Emission Tomography Values. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1097/00004647-199804000-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.