Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 158

The DOI matches its Crossref record.

Comparison of the Transient Equilibrium and Continuous Infusion Method for Quantitative PET Analysis of [11C]Raclopride Binding

Ito, Hiroshi, Hietala, Jarmo, Blomqvist, Gunnar, Halldin, Christer, Farde, Lars · 1998 · Journal of Cerebral Blood Flow & Metabolism

Abstract

Several approaches have been applied for quantification of D 2 dopamine receptors in positron emission tomography studies using [11 C]raclopride. Initial approaches were based on analyses of data obtained after rapid bolus injection of [11 C]raclopride. A continuous infusion paradigm has more recently been applied. The current study compares these approaches in healthy men. Two positron emission tomography measurements were performed in each of six healthy men, the first with rapid bolus injection and the second with continuous infusion of [11 C]raclopride. In rapid bolus injection, the binding potential was calculated by the following methods. One approach is the kinetic analysis using the standard three-compartment model. Another is to define a transient equilibrium at the moment when the specific binding reaches its maximum. In continuous infusion, binding potential was calculated by using time-activity data at equilibrium condition. All methods gave almost identical binding potential, representing cross-validation of these methods. The continuous infusion method can provide “true” equilibrium condition. The kinetic analysis is a sophisticated approach but requires determination of an arterial input function. The transient equilibrium method thus is suitable for routine clinical research, since it does not require determination of an arterial input function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004647-199809000-00003

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Ito, H., Hietala, J., Blomqvist, G., Halldin, C., & Farde, L.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1998-09
Volume
18
Issue
9
Pages
941-950
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W1996065499
Cited by
158
References
0
FWCI
8.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of the Transient Equilibrium and Continuous Infusion Method for Quantitative PET Analysis of [11C]Raclopride Binding. https://app.cochat.ai/papers/10.1097/00004647-199809000-00003
The paper
Ito, H., Hietala, J., Blomqvist, G., Halldin, C., & Farde, L. (1998). Comparison of the Transient Equilibrium and Continuous Infusion Method for Quantitative PET Analysis of [11C]Raclopride Binding. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1097/00004647-199809000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.