Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 169

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Strategy for Removing the Bias in the Graphical Analysis Method

Open access
Logan, Jean, Fowler, Joanna S., Volkow, Nora D., Ding, Yu Shin, Wang, Gene-Jack, Alexoff, David L. · 2001 · Journal of Cerebral Blood Flow & Metabolism

Abstract

The graphical analysis method, which transforms multiple time measurements of plasma and tissue uptake data into a linear plot, is a useful tool for rapidly obtaining information about the binding of radioligands used in PET studies. The strength of the method is that it does not require a particular model structure. However, a bias is introduced in the case of noisy data resulting in the underestimation of the distribution volume (DV), the slope obtained from the graphical method. To remove the bias, a modification of the method developed by Feng et al. (1993) , the generalized linear least squares (GLLS) method, which provides unbiased estimates for compartment models was used. The one compartment GLLS method has a relatively simple form, which was used to estimate the DV directly and as a smoothing technique for more general classes of model structures. In the latter case, the GLLS method was applied to the data in two parts, that is, one set of parameters was determined for times 0 to T 1 and a second set from T 1 to the end time. The curve generated from these two sets of parameters then was used as input to the graphical method. This has been tested using simulations of data similar to that of the PET ligand [11 C]- d-threo-methylphenidate (MP, DV = 35 mL/mL) and 11 C raclopride (RAC, DV = 1.92 mL/mL) and compared with two examples from image data with the same tracers. The noise model was based on counting statistics through the half-life of the isotope and the scanning time. Five hundred data sets at each noise level were analyzed. Results (DV) for the graphical analysis (DV g), the nonlinear least squares (NLS) method (DV nls), the one-tissue compartment GLLS method (DV f), and the two part GLLS followed by graphical analysis (DV fg) were compared. DVFG was found to increase somewhat with increasing noise and in some data sets at high noise levels no estimate could be obtained. However, at intermediate levels it provided a good estimation of the true DV. This method was extended to use a reference tissue in place of the input function to generate the distribution volume ratio (DVR) to the reference region. A linearized form of the simplified reference tissue method of Lammertsma and Hume (1996) was used. The DVR generated directly from the model (DVR fl) was compared with DVR fg (determined from a “smoothed” uptake curve as for DV fg) using the graphical method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004647-200103000-00014

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 169

Metadata

Authors
Logan, J., Fowler, J. S., Volkow, N. D., Ding, Y. S., Wang, G.-J., & Alexoff, D. L.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
2001-03
Volume
21
Issue
3
Pages
307-320
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W1986159971
Cited by
169
References
1
FWCI
6.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Strategy for Removing the Bias in the Graphical Analysis Method. https://app.cochat.ai/papers/10.1097/00004647-200103000-00014
The paper
Logan, J., Fowler, J. S., Volkow, N. D., Ding, Y. S., Wang, G.-J., & Alexoff, D. L. (2001). A Strategy for Removing the Bias in the Graphical Analysis Method. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1097/00004647-200103000-00014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.