The DOI matches its Crossref record.
Technical and Practical Aspects of Magnetic Nerve Stimulation
Abstract
Magnetic stimulators consist of a high-voltage (400 V to more than 3 kV), high-current (4 kA to more than 20 kA) discharge system producing a brief pulse of magnetic field (1-10 T lasting up to a few milliseconds). In order to ensure safety and reliability, care has to be taken in the construction of magnetic stimulators and especially their stimulating coils, which may come into contact with the patient, by the use of adequate mechanical and electrical insulation and the incorporation of sensors to monitor temperature, voltage, etc. Where possible, equipment should be manufactured to comply with safety standards such as UL504 and IEC601. The effectiveness of a magnetic stimulator depends on many parameters such as the maximization of the peak coil energy, fast magnetic field rise times, and good coil design. It is also important to choose a coil based on its intended clinical application and not simply on account of its high magnetic field strength. A small coil, producing a high surface magnetic field, is suitable in the stimulation of superficial nerves, whereas a larger coil, with a low magnetic field intensity, may well be more suitable for the stimulation of deep nerves. Double, figure-eight, or butterfly coils produce more localised induced currents allowing for more selective stimulation. The exposure of the brain to high magnetic field strengths can also be reduced by using larger coils.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Okamoto, M., Dan, H., Sakamoto, K., Takeo, K., Shimizu, K., Kohno, S., Oda, I., Isobe, S., Suzuki, T., Kohyama, K., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.08.026 · Cited by 1,320
A practical guide to diagnostic transcranial magnetic stimulation: Report of an IFCN committee
Groppa, S., Oliviero, A., Eisen, A., Quartarone, A., Cohen, L. G., Mall, V., Kaelin-Lang, A., Mima, T., Rossi, S., Thickbroom, G. W., et al. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.01.010 · Cited by 1,274
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.02.005 · Cited by 1,073
Transcranial magnetic stimulation and cognitive neuroscience
Walsh, V., & Cowey, A. (2000) · Nature Reviews Neuroscience · doi:10.1038/35036239 · Cited by 814
Spatial registration of multichannel multi-subject fNIRS data to MNI space without MRI
Singh, A. K., Okamoto, M., Dan, H., Jurcak, V., & Dan, I. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.019 · Cited by 704
Metadata
- Authors
- Jalinous, R.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1991-01
- Volume
- 8
- Issue
- 1
- Pages
- 10-25
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2044002620
- Cited by
- 203
- References
- 0
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Technical and Practical Aspects of Magnetic Nerve Stimulation. https://app.cochat.ai/papers/10.1097/00004691-199101000-00004
- The paper
- Jalinous, R. (1991). Technical and Practical Aspects of Magnetic Nerve Stimulation. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-199101000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.