Technical and Practical Aspects of Magnetic Nerve Stimulation
The DOI matches its Crossref record.
Abstract
Magnetic stimulators consist of a high-voltage (400 V to more than 3 kV), high-current (4 kA to more than 20 kA) discharge system producing a brief pulse of magnetic field (1-10 T lasting up to a few milliseconds). In order to ensure safety and reliability, care has to be taken in the construction of magnetic stimulators and especially their stimulating coils, which may come into contact with the patient, by the use of adequate mechanical and electrical insulation and the incorporation of sensors to monitor temperature, voltage, etc. Where possible, equipment should be manufactured to comply with safety standards such as UL504 and IEC601. The effectiveness of a magnetic stimulator depends on many parameters such as the maximization of the peak coil energy, fast magnetic field rise times, and good coil design. It is also important to choose a coil based on its intended clinical application and not simply on account of its high magnetic field strength. A small coil, producing a high surface magnetic field, is suitable in the stimulation of superficial nerves, whereas a larger coil, with a low magnetic field intensity, may well be more suitable for the stimulation of deep nerves. Double, figure-eight, or butterfly coils produce more localised induced currents allowing for more selective stimulation. The exposure of the brain to high magnetic field strengths can also be reduced by using larger coils.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Okamoto, M., Dan, H., Sakamoto, K., Takeo, K., Shimizu, K., Kohno, S., Oda, I., Isobe, S., Suzuki, T., Kohyama, K., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.08.026 · Cited by 1,320
A practical guide to diagnostic transcranial magnetic stimulation: Report of an IFCN committee
Groppa, S., Oliviero, A., Eisen, A., Quartarone, A., Cohen, L. G., Mall, V., Kaelin-Lang, A., Mima, T., Rossi, S., Thickbroom, G. W., et al. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.01.010 · Cited by 1,274
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.02.005 · Cited by 1,073
Transcranial magnetic stimulation and cognitive neuroscience
Walsh, V., & Cowey, A. (2000) · Nature Reviews Neuroscience · doi:10.1038/35036239 · Cited by 814
Spatial registration of multichannel multi-subject fNIRS data to MNI space without MRI
Singh, A. K., Okamoto, M., Dan, H., Jurcak, V., & Dan, I. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.019 · Cited by 704
Parietal cortex and representation of the mental Self
Lou, H. C., Luber, B., Crupain, M., Keenan, J. P., Nowak, M., Kjaer, T. W., Sackeim, H. A., & Lisanby, S. H. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0400049101 · Cited by 631
The cortical topography of human swallowing musculature in health and disease
Hamdy, S., Aziz, Q., Rothwell, J. C., Singh, K. D., Barlow, J., Hughes, D. G., Tallis, R. C., & Thompson, D. G. (1996) · Nature Medicine · doi:10.1038/nm1196-1217 · Cited by 502
Pascual-Leone, A. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0476 · Cited by 454
Impact of the gyral geometry on the electric field induced by transcranial magnetic stimulation
Thielscher, A., Opitz, A., & Windhoff, M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.061 · Cited by 439
Fitzgerald, P. B., Hoy, K., McQueen, S., Maller, J. J., Herring, S., Segrave, R., Bailey, M., Been, G., Kulkarni, J., & Daskalakis, Z. J. (2009) · Neuropsychopharmacology · doi:10.1038/npp.2008.233 · Cited by 417
Evidence of activity-dependent withdrawal of corticospinal projections during human development
Eyre, J. A., Taylor, J. P., Villagra, F., Smith, M., & Miller, S. (2001) · Neurology · doi:10.1212/wnl.57.9.1543 · Cited by 402
Stokes, M. G., Chambers, C. D., Gould, I. C., Henderson, T. R., Janko, N. E., Allen, N. B., & Mattingley, J. B. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00067.2005 · Cited by 367
Three-Dimensional Head Model Simulation of Transcranial Magnetic Stimulation
Wagner, T. A., Zahn, M., Grodzinsky, A. J., & Pascual-Leone, A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827925 · Cited by 348
Eyre, J. A., Miller, S., Clowry, G. J., Conway, E. A., & Watts, C. (2000) · Brain · doi:10.1093/brain/123.1.51 · Cited by 345
Brain-gut axis in health and disease
Aziz, Q., & Thompson, D. G. (1998) · Gastroenterology · doi:10.1016/s0016-5085(98)70540-2 · Cited by 329
Temporal aspects of visual search studied by transcranial magnetic stimulation
Ashbridge, E. (1997) · Neuropsychologia · doi:10.1016/s0028-3932(97)00003-1 · Cited by 308
Thielscher, A., & Kammer, T. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.02.019 · Cited by 294
Explaining oropharyngeal dysphagia after unilateral hemispheric stroke
Hamdy, S., Aziz, Q., Rothwell, J. C., Crone, R., Hughes, D., Tallis, R. C., & Thompson, D. G. (1997) · The Lancet · doi:10.1016/s0140-6736(97)02068-0 · Cited by 284
Bestmann, S., Baudewig, J., Siebner, H. R., Rothwell, J. C., & Frahm, J. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.07.028 · Cited by 262
Fitzgerald, P. B., Oxley, T. J., Laird, A. R., Kulkarni, J., Egan, G. F., & Daskalakis, Z. J. (2006) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2006.04.006 · Cited by 254
Automated cortical projection of head-surface locations for transcranial functional brain mapping
Okamoto, M., & Dan, I. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.018 · Cited by 242
Distance-adjusted motor threshold for transcranial magnetic stimulation
Stokes, M. G., Chambers, C. D., Gould, I. C., English, T., McNaught, E., McDonald, O., & Mattingley, J. B. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.004 · Cited by 220
“The physical principles of electromagnetic induction state that the magnetic flux density decreases with distance; therefore, the effect of TMS is inversely proportional to the distance from the stimulating coil (Jalinous, 1991).”
BackgroundInfluentialTask–specific impairments and enhancements induced by magnetic stimulation of human visual area V5
Walsh, V., Ellison, A., Battelli, L., & Cowey, A. (1998) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1998.0328 · Cited by 213
“The magnetic pulse is supplied to the coil from a storage capacitor charged to approximately 4 kVand has an estimated rise time of 0.2ms and a duration of up to 1ms (Jalinous 1991).”
BackgroundWagner, T., Rushmore, J., Eden, U., & Valero-Cabre, A. (2009) · Cortex · doi:10.1016/j.cortex.2008.10.002 · Cited by 188
“Received 19 July 2008 Reviewed 7 September 2008 Accepted 10 October 2008 Published online -”
Bilateral magnetic stimulation of the phrenic nerves from an anterolateral approach.
Mills, G. H., Kyroussis, D., Hamnegard, C. H., Polkey, M. I., Green, M., & Moxham, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.4.8887614 · Cited by 183
Oliveri, M., Turriziani, P., Carlesimo, G. A., Koch, G., Tomaiuolo, F., Panella, M., & Caltagirone, C. (2001) · Cerebral Cortex · doi:10.1093/cercor/11.7.606 · Cited by 182
“With the adopted coil, the magnetic pulse has a rise time of ∼200 µs and a duration of 1 ms, but the effects in the underlying cortical region are reported to last for up to 10 ms (Jalinous, 1991; Ilmoniemi et al., 1997).”
BackgroundPhysiological motor asymmetry in human handedness: evidence from transcranial magnetic stimulation
Triggs, W. J., Calvanio, R., Macdonell, R. A. L., Cros, D., & Chiappa, K. H. (1994) · Brain Research · doi:10.1016/0006-8993(94)91026-x · Cited by 180
Grammatical Distinctions in the Left Frontal Cortex
Shapiro, K. A., Pascual-Leone, A., Mottaghy, F. M., Gangitano, M., & Caramazza, A. (2001) · Journal of Cognitive Neuroscience · doi:10.1162/08989290152541386 · Cited by 179
“The focality of the brain effects of TMS depend on coil geometry; the small 8- shaped coil employed in the present experiment affects functionally small volumes of cortex with a specificity similar to PET or fMRI (Jalinous, 1991).”
MethodPeterchev, A. V., Jalinous, R., & Lisanby, S. H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900540 · Cited by 174
“deteriorates the electrical efficiency since lower voltages are associates with inefficient energy transfer to the coil [10].”
BackgroundSelf-citationMagnetic stimulation studies of visual cognition
Walsh, V., & Cowey, A. (1998) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(98)01134-6 · Cited by 164
Kammer, T., Puls, K., Erb, M., & Grodd, W. (2005) · Experimental Brain Research · doi:10.1007/s00221-004-1992-0 · Cited by 160
“We further cannot exclude that areas close to the lateral wings of the figureof-eight coil were stimulated in addition to the area in the center of the coil (Jalinous 1991).”
BackgroundTissue heterogeneity as a mechanism for localized neural stimulation by applied electric fields
Miranda, P. C., Correia, L., Salvador, R., & Basser, P. J. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/18/009 · Cited by 83
Modak, A., & Fitzgerald, P. B. (2021) · The World Journal of Biological Psychiatry · doi:10.1080/15622975.2021.1907710 · Cited by 56
“Given that the standard 70mm figure-of-8 TMS coil is thought to stimulate a 2 cm squared area under the cortical surface (Jalinous 1991), it is expected that standard targeting techniques may inadvertently stimulate the intended target coordinates to varying degrees.”
BackgroundNumerical analysis and design of single-source multicoil TMS for deep and focused brain stimulation
Gomez, L., Cajko, F., Hernandez-Garcia, L., Grbic, A., & Michielssen, E. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264632 · Cited by 55
Metadata
- Authors
- Jalinous, R.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1991-01
- Volume
- 8
- Issue
- 1
- Pages
- 10-25
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2044002620
- Cited by
- 203
- References
- 0
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.