Abstract
In order to clarify the generator mechanism of pain-related evoked potentials (pain EPs), we studied the scalp topography of the pain EPs following CO2 laser stimulation of hand dorsum by using balanced sternovertebral electrodes as the noncephalic reference in 11 normal volunteers. We also examined the effects of predictive warning signal (light-emitting diode) on the pain EPs. In both the warned and unwarned conditions, all of the 22 hand stimulations showed a large negative component (N2) at the peak latency of about 213 ms followed by a large positive component (P2) at the peak latency of about 329 ms. A preceding small negative component (N1) at the peak latency of about 148 ms was detected in 12 of the 22 hand stimulations in the warned condition and in 13 of the 22 hand stimulations in the unwarned condition. P2 was significantly larger and occurred earlier in the warned condition than in the unwarned condition, whereas other components did not differ between the two conditions, suggesting that an increased attention of the subject to the stimulus influenced the generator mechanism of the P2 component. With regards to the scalp topography, N2 was maximal at Cz and widespread transversely to both sides, whereas P2 was maximal at Cz or Pz and spread more posteriorly than N2. These findings suggest that P2 is generated by a different mechanism from N2 and is most likely associated with pain-related cognitive function. N1 was localized to the contralateral central and midtemporal areas, confirming that the nociceptive inputs are perceived in the sensory cortex in humans. The question as to whether the N1 component is generated in the hand area of the primary somatosensory cortex or in the secondary somatosensory cortex, or in both areas, remains to be solved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human brain mechanisms of pain perception and regulation in health and disease
Apkarian, A. V., Bushnell, M. C., Treede, R., & Zubieta, J. (2005) · European Journal of Pain · doi:10.1016/j.ejpain.2004.11.001 · Cited by 3,126
Sawamoto, N., Honda, M., Okada, T., Hanakawa, T., Kanda, M., Fukuyama, H., Konishi, J., & Shibasaki, H. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-19-07438.2000 · Cited by 520
Self-citationElectrophysiological studies of myoclonus
Shibasaki, H., & Hallett, M. (2005) · Muscle & Nerve · doi:10.1002/mus.20234 · Cited by 302
Self-citationTreede, R.-D., Apkarian, V. A., Bromm, B., Greenspan, J. D., & Lenz, F. A. (2000) · Pain · doi:10.1016/s0304-3959(00)00350-x · Cited by 300
Legrain, V., Guérit, J.-M., Bruyer, R., & Plaghki, L. (2002) · Pain · doi:10.1016/s0304-3959(02)00051-9 · Cited by 274
“N1 was better observed after strong stimuli, at the contralateral midtemporal leads, and often with a frontal or nose reference (Treede et al., 1988; Kunde and Treede, 1993; Miyazaki et al., 1994; Spiegel et al., 1996; Valeriani et al., 1996).”
Metadata
- Authors
- Miyazaki, M., Shibasaki, H., Kanda, M., Xu, X., Shindo, K., Honda, M., Ikeda, A., Nagamine, T., Kaji, R., & Kimura, J.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1994-03
- Volume
- 11
- Issue
- 2
- Pages
- 242-254
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2020539508
- Cited by
- 75
- References
- 0
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Generator Mechanism of Pain-Related Evoked Potentials Following CO2 Laser Stimulation of the Hand: Scalp Topography and Effect of Predictive Warning Signal. https://app.cochat.ai/papers/10.1097/00004691-199403000-00010
- The paper
- Miyazaki, M., Shibasaki, H., Kanda, M., Xu, X., Shindo, K., Honda, M., Ikeda, A., Nagamine, T., Kaji, R., & Kimura, J. (1994). Generator Mechanism of Pain-Related Evoked Potentials Following CO2 Laser Stimulation of the Hand: Scalp Topography and Effect of Predictive Warning Signal. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-199403000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.