Identification of Electrocorticogram Patterns as the Basis for a Direct Brain Interface
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study reports on the first step in the development of a direct brain interface based on the identification of event-related potentials (ERPs) from an electrocorticogram obtained from the surface of the cortex. Ten epilepsy surgery patients, undergoing monitoring with subdural electrode strips and grid arrays, participated in this study. Electrocorticograms were continuously recorded while subjects performed multiple repetitions for each of several motor actions. ERP templates were identified from action-triggered electrocorticogram averages using an amplitude criterion. At least one ERP template was identified for all 10 subjects and in 56% of all electrode-recording sets resulting from a subject performing an action. These results were obtained with electrodes placed solely for clinical purposes and not for research needs. Eighty-two percent of the identified ERPs began before the trigger, indicating the presence of premovement ERP components. The regions yielding the highest probability of valid ERP identification were the sensorimotor cortex (precentral and postcentral gyri) and anterior frontal lobe, although a number were recorded from other areas as well. The recording locations for multiple ERPs arising from the performance of a specific action were usually found on close-by electrodes. ERPs associated with different actions were occasionally identified from the same recording site but often had noticeably different characteristics. The results of this study support the use of ERPs recorded from the cortical surface as a basis for a direct brain interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
“Epidural and subdural electrodes can provide EEG with high topographical resolution, and intracortical electrodes can follow the activity of individual neurons (Schmidt, 1980; Ikeda and Shibbasaki, 1992; Heetderks and Schmidt, 1995; Levine et al., 1999, 2000; Wolpaw et al., 2000a).”
BackgroundBrain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“[68] designed a BCI which classified motor actions on the basis of the identification of the event-related potentials (ERP) using ECoG.”
MethodA brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Spectral Changes in Cortical Surface Potentials during Motor Movement
Miller, K. J., Leuthardt, E. C., Schalk, G., Rao, R. P. N., Anderson, N. R., Moran, D. W., Miller, J. W., & Ojemann, J. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3886-06.2007 · Cited by 738
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Invasive recordings from the human brain: clinical insights and beyond
Engel, A. K., Moll, C. K. E., Fried, I., & Ojemann, G. A. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1585 · Cited by 419
Real-time EEG analysis with subject-specific spatial patterns for a brain-computer interface (BCI)
Guger, C., Ramoser, H., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895947 · Cited by 383
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Brain–Computer Interfaces: A Gentle Introduction
Graimann, B., Allison, B., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_1 · Cited by 298
Graz-BCI: state of the art and clinical applications
Pfurtscheller, G., Neuper, C., Muller, G. R., Obermaier, B., Krausz, G., Schlogl, A., Scherer, R., Graimann, B., Keinrath, C., Skliris, D., et al. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814454 · Cited by 286
A direct brain interface based on event-related potentials
Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Rohde, M. M., Passaro, E. A., Ross, D. A., Elisevich, K. V., & Smith, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847809 · Cited by 197
Self-citationGeorge, J. S., Strunk, J., Mak-McCully, R., Houser, M., Poizner, H., & Aron, A. R. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.07.013 · Cited by 162
“EEG studies of going (movement) reveal that, during initiation, beta power is suppressed and gamma power is increased; and post-movement, there is an increased beta power over sensorimotor regions (Engel and Fries, 2010; Leuthardt et al., 2004; Levine et al., 1999; Pfurtscheller et al., 1996, 2003; Rohde et al., 2002).”
Background
Metadata
- Authors
- Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Passaro, E. A., Rohde, M. M., & Ross, D. A.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1999-09
- Volume
- 16
- Issue
- 5
- Pages
- 439
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2054752348
- Cited by
- 85
- References
- 1
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.