The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Safety of Intraoperative Transcranial Electrical Stimulation Motor Evoked Potential Monitoring
Abstract
This article reviews intraoperative transcranial electrical stimulation (TES) motor evoked potential (MEP) monitoring safety based on comparison with other clinical and experimental brain stimulation methods and clinical experience in more than 15000 cases. Comparative analysis indicates that brain damage and kindling are highly unlikely. There have been remarkably few adverse events. Pulse train TES-induced or coincidental seizures (n = 5) are rare, probably because of very brief (<0.03 second) stimuli, anesthesia, and the general absence of predisposing cerebral conditions. Soft bite blocks may prevent tongue or lip laceration (n = 29) or mandibular fracture (n = 1). Rare cardiac arrhythmia (n = 5) and intraoperative awareness (n = 1) may be coincidental. Minor scalp burns (n = 2) are rare. Although possible, no spinal epidural recording electrode complications or injuries resulting from TES-induced movement were found. There have been no recognized adverse neuropsychological effects, headaches, or endocrine disturbances. Comprehensive relative contraindications include epilepsy, cortical lesions, convexity skull defects, raised intracranial pressure, cardiac disease, proconvulsant medications or anesthetics, intracranial electrodes, vascular clips or shunts, and cardiac pacemakers or other implanted biomedical devices. Otherwise unexplained intraoperative seizures and possibly arrhythmias are indications to abort TES. With appropriate precautions in expert hands, the well-established benefits of TES MEP monitoring decidedly outweigh the associated risks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A permanent change in brain function resulting from daily electrical stimulation
Goddard, G. V., McIntyre, D. C., & Leech, C. K. (1969) · Experimental Neurology · doi:10.1016/0014-4886(69)90128-9 · Cited by 3,052
Wassermann, E. M. (1998) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0168-5597(97)00096-8 · Cited by 2,293
Stimulation of the cerebral cortex in the intact human subject
Merton, P. A., & Morton, H. B. (1980) · Nature · doi:10.1038/285227a0 · Cited by 1,094
Anticoagulants and Spinal-Epidural Anesthesia
Vandermeulen, E. P., Aken, H. V., & Vermylen, J. (1994) · Anesthesia & Analgesia · doi:10.1213/00000539-199412000-00024 · Cited by 873
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Modification of Cortical Stimulation for Motor Evoked Potentials under General Anesthesia
Taniguchi, M., Cedzich, C., Taniguchi, M., Cedzich, C., & Schramm, J. (1993) · Neurosurgery · doi:10.1227/00006123-199302000-00011 · Cited by 554
Barker, A. T., Freeston, I. L., Jalinous, R., & Jarratt, J. A. (1987) · Neurosurgery · doi:10.1097/00006123-198701000-00024 · Cited by 512
Cedzich, C., Taniguchi, M., Schäfer, S., & Schramm, J. (1996) · Neurosurgery · doi:10.1097/00006123-199605000-00023 · Cited by 344
Neurologic Deficits following Epidural or Spinal Anesthesia
Kane, R. E. (1981) · Anesthesia & Analgesia · doi:10.1213/00000539-198103000-00006 · Cited by 338
Stimulus Intensity, Seizure Threshold, and Seizure Duration
Sackeim, H. A., Devanand, D. P., & Prudic, J. (1991) · Psychiatric Clinics of North America · doi:10.1016/s0193-953x(18)30271-5 · Cited by 336
Cited by
MacDonald, D. B., Skinner, S., Shils, J., & Yingling, C. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.07.025 · Cited by 568
Self-citationSala, F., Palandri, G., Basso, E., Lanteri, P., Deletis, V., Faccioli, F., & Bricolo, A. (2006) · Neurosurgery · doi:10.1227/01.neu.0000215948.97195.58 · Cited by 452
Intraoperative Motor Evoked Potential Monitoring: Overview and Update
MacDonald, D. B. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9033-0 · Cited by 348
Self-citationTranscranial current stimulation focality using disc and ring electrode configurations: FEM analysis
Datta, A., Elwassif, M., Battaglia, F., & Bikson, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/007 · Cited by 320
Metadata
- Authors
- MacDonald, D. B.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2002-10
- Volume
- 19
- Issue
- 5
- Pages
- 416-429
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2078465484
- Cited by
- 342
- References
- 59
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety of Intraoperative Transcranial Electrical Stimulation Motor Evoked Potential Monitoring. https://app.cochat.ai/papers/10.1097/00004691-200210000-00005
- The paper
- MacDonald, D. B. (2002). Safety of Intraoperative Transcranial Electrical Stimulation Motor Evoked Potential Monitoring. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-200210000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.