Cited by 708Neuroscience and Neural EngineeringNeurological disorders and treatmentsPain Management and Treatment

Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation

McCreery, D.B., Agnew, W.F., Yuen, T.G.H., Bullara, L.·1990·IEEE Transactions on Biomedical Engineering

Abstract

The possibility of neural injury during prolonged electrical stimulation of the brain imposes some constraints on the use of this technique for therapeutic and experimental applications. Stimulating electrodes of various sizes were used to investigate the interactions of two stimulus parameters, charge density and charge per phase, in determining the threshold of neural injury induced by electrical stimulation. Platinum electrodes ranging in size from 0.002 to 0.5 cm2 were implanted over the parietal cortex of adult cats. Penetrating microelectrodes fabricated from iridium, with surface areas of 65 +/- 3 x 10(-6) cm2 were inserted into the parietal cortex. Ten days after implantation, the electrodes were pulsed continuously for 7h using charge balanced, current regulated, symmetric pulse pairs, 400 microseconds per phase in duration, at a repetition rate of 50 Hz. The animals were perfused immediately after the stimulation for histologic evaluation of the brain tissue subjacent to the electrode sites. The results show that charge density (as measured at the surface of the stimulating electrode), and charge per phase, interact in a synergistic manner to determine the threshold of stimulation-induced neural injury. This interaction occurs over a wide range of both parameters; for charge density from at least 10 to 800 microC/cm2 and, for charge per phase, from at least 0.05 to 5.0 microC per phase. The significance of these findings in elucidating the mechanisms underlying stimulation-induced injury is discussed.

Integrity signals

Registry

Crossref · 10.1109/10.102812

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Shannon derived a model for safe stimulation largely based on experimental data by McCreery et al.

    “Shannon derived a model for safe stimulation [65] largely based on experimental data by McCreery et al. [64].”
  • A large part of the literature and of our knowledge about neural stimulation is based on animal studies mostly conducted in the 1980s and 1990s.

    “Consequently, a large part of the literature and of our knowledge about neural stimulation is based on animal studies mostly conducted in the 1980s and 1990s [43–45, 62–64, 75, 92, 94, 96, 99, 100].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L.
Affiliations
Huntington Medical Research Institutes (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
1990
Volume
37
Issue
10
Pages
996-1001
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2160326715
Cited by
708
References
18
Citations by year
2026: 19 · 2025: 18 · 2024: 13 · 2023: 24 · 2022: 30 · 2021: 29 · 2020: 32 · 2019: 28 · 2018: 33 · 2017: 42 · 2016: 33 · 2015: 30 · 2014: 32 · 2013: 38 · 2012: 18
FWCI
1.70
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Neurological Disorders and Stroke (N01-NS-6-2397)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Neurology › Neurological disorders and treatments
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
Keywords
electrical brain stimulation, nerve injury, charge density, platinum electrode, parietal cortex, electrode size
MeSH terms
Animals, Brain Injuries, Cats, Electric Conductivity, Electric Stimulation, Electrodes, Neurons

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review