The DOI matches its Crossref record.
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Abstract
Computed transverse section emission tomography using 99mTc with the Anger camera is compared to positron annihilation coincident detection using a ring of crystals and 68Ga. The single-photon system has a line spread function (LSF) of 9 mm full width at half maximum (FWHM) at the collimator and gives a transverse section reconstruction LSF of 11 mm FWHM with 144 views. The positron ring has a LSF of 6 mm at the center with a transverse section reconstruction LSF of 7.5 mm FWHM. Correction for uniformity of detector response and accurate center of rotation determination is essential in both techniques. The signal-to-noise ratio in a reconstruction is diminished by a factor of 1.2 x (number of resolution elements)1/4 over that expected from the average number of events per resolution element. Attenuation compensation causes more noise to appear in the center than the edge for both modes and an average increase in uncertainty of 30%. The effects of attenuation result in more loss of data for positron coincidence imaging than for single-photon imaging even at energies of 80 keV. For a 20-cm cylinder imaged in transverse section, only 20% of the positron annihilation events are not scattered; however, at 140 keV, 40% of the photons are not scattered. The relative crystal efficiency gives single-photon imaging an advantage of 5. On the other hand, the solid angle advantage of positron photon coincidence imaging is about 100 for the comparisons of this paper. Taking these factors into account, we find positron-computed section imaging has a tenfold increase in sensitivity over multiple-view imaging with the scintillation camera, which gives multiple sections but requires camera or patient rotation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Study of Cerebral Function with Positron Computed Tomography
Phelps, M. E., Mazziotta, J. C., & Huang, S.-C. (1982) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1982.14 · Cited by 378
The Use of Sieves to Stabilize Images Produced with the EM Algorithm for Emission Tomography
Snyder, D. L., & Miller, M. I. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4334521 · Cited by 278
Positron emission tomography and its application to the study of cerebrovascular disease in man.
Powers, W. J., & Raichle, M. E. (1985) · Stroke · doi:10.1161/01.str.16.3.361 · Cited by 268
Computerized tomography with X-ray, emission, and ultrasound sources
Kak, A. C. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11440 · Cited by 264
Metadata
- Authors
- Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1977-01
- Volume
- 1
- Issue
- 1
- Pages
- 131-145
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1978298572
- Cited by
- 200
- References
- 0
- FWCI
- 13.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters. https://app.cochat.ai/papers/10.1097/00004728-197701000-00015
- The paper
- Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977). Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-197701000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.