Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 443

The DOI matches its Crossref record.

Quantitation in Positron Emission Computed Tomography: 2. Effects of Inaccurate Attenuation Correction

Huang, Sung-Cheng, Hoffman, Edward J., Phelps, Michael E., Kuhl, David E.·1979·Journal of Computer Assisted Tomography

Abstract

Effects of inaccurate attenuation correction on quantitation in positron emission computed tomography were investigated by both computer simulation and theoretical analysis, followed by experimental verification with phantom measurements. It was found that, due to the finite width of detector responses, compensation of scan measurements by measured attenuation correction factors does not completely correct for attenuation. For FWHM > 1.8 cm, errors in object size and in activity levels of reconstructed images are more than 4%. Mismatches between true and assumed attenuation media are found to give large errors. These mismatches include object shift, incorrect size and shape, uniform and nonuniform mismatches in attenuation coefficients, and nonzero background levels. Errors as large as 14% in the reconstructed activity level can be introduced by a 5 mm shift in object position. A 5% error in the cylinder diameter can give differences between the total reconstructed activity and true value more than 12%. Strong image distortions, which could lead to incorrect interpretations of images, are created by object shift and by nonuniform mismatches in attenuation coefficient. It was also found that statistical noise in measured attenuation correction factors can significantly increase noise levels in images, resulting in lower effective total counts for the emission scan. Effective total counts can be estimated as Neff = kNxmNem/(Nem + kNxm), where Nem and Nxm are total counts in emission and transmission scans, and k is a scanner dependent factor, which accounts for configuration differences. Index Terms: Emission computed tomography—Attenuation values—Noise—Image reconstruction—Data processing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-197912000-00018

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 443

Metadata

Authors
Huang, S.-C., Hoffman, E. J., Phelps, M. E., & Kuhl, D. E.
Venue
Journal of Computer Assisted Tomography
Published
1979-12
Volume
3
Issue
6
Pages
804-814
ISSN
0363-8715 (ISSN-L)
OpenAlex
W3001275908
Cited by
443
References
0
FWCI
5.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitation in Positron Emission Computed Tomography: 2. Effects of Inaccurate Attenuation Correction. https://app.cochat.ai/papers/10.1097/00004728-197912000-00018
The paper
Huang, S.-C., Hoffman, E. J., Phelps, M. E., & Kuhl, D. E. (1979). Quantitation in Positron Emission Computed Tomography: 2. Effects of Inaccurate Attenuation Correction. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-197912000-00018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.