Quantitation in Positron Emission Computed Tomography: 2. Effects of Inaccurate Attenuation Correction
The DOI matches its Crossref record.
Abstract
Effects of inaccurate attenuation correction on quantitation in positron emission computed tomography were investigated by both computer simulation and theoretical analysis, followed by experimental verification with phantom measurements. It was found that, due to the finite width of detector responses, compensation of scan measurements by measured attenuation correction factors does not completely correct for attenuation. For FWHM > 1.8 cm, errors in object size and in activity levels of reconstructed images are more than 4%. Mismatches between true and assumed attenuation media are found to give large errors. These mismatches include object shift, incorrect size and shape, uniform and nonuniform mismatches in attenuation coefficients, and nonzero background levels. Errors as large as 14% in the reconstructed activity level can be introduced by a 5 mm shift in object position. A 5% error in the cylinder diameter can give differences between the total reconstructed activity and true value more than 12%. Strong image distortions, which could lead to incorrect interpretations of images, are created by object shift and by nonuniform mismatches in attenuation coefficient. It was also found that statistical noise in measured attenuation correction factors can significantly increase noise levels in images, resulting in lower effective total counts for the emission scan. Effective total counts can be estimated as Neff = kNxmNem/(Nem + kNxm), where Nem and Nxm are total counts in emission and transmission scans, and k is a scanner dependent factor, which accounts for configuration differences. Index Terms: Emission computed tomography—Attenuation values—Noise—Image reconstruction—Data processing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Subgenual prefrontal cortex abnormalities in mood disorders
Drevets, W. C., Price, J. L., Simpson, J. R., Todd, R. D., Reich, T., Vannier, M., & Raichle, M. E. (1997) · Nature · doi:10.1038/386824a0 · Cited by 2,693
Phelps, M. E., Huang, S. C., Hoffman, E. J., Selin, C., Sokoloff, L., & Kuhl, D. E. (1979) · Annals of Neurology · doi:10.1002/ana.410060502 · Cited by 2,418
Self-citationThe subgenual anterior cingulate cortex in mood disorders
Drevets, W. C., Savitz, J., & Trimble, M. (2008) · CNS Spectrums · doi:10.1017/s1092852900013754 · Cited by 1,109
Noninvasive determination of local cerebral metabolic rate of glucose in man
Huang, S. C., Phelps, M. E., Hoffman, E. J., Sideris, K., Selin, C. J., & Kuhl, D. E. (1980) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1980.238.1.e69 · Cited by 925
Self-citationPET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
Discrimination between Alzheimer dementia and controls by automated analysis of multicenter FDG PET
Herholz, K., Salmon, E., Perani, D., Baron, J.-C., Holthoff, V., Frölich, L., Schönknecht, P., Ito, K., Mielke, R., & Kalbe, E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1208 · Cited by 832
Pet imaging of serotonin 1A receptor binding in depression
Drevets, W. C., Frank, E., Price, J. C., Kupfer, D. J., Holt, D., Greer, P. J., Huang, Y., Gautier, C., & Mathis, C. (1999) · Biological Psychiatry · doi:10.1016/s0006-3223(99)00189-4 · Cited by 666
Levin, C. S., & Hoffman, E. J. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/3/019 · Cited by 551
Self-citationFunctional neuroimaging studies of depression: The anatomy of melancholia
Drevets, W. C. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.341 · Cited by 500
Drevets, W. C., Price, J. L., Bardgett, M. E., Reich, T., Todd, R. D., & Raichle, M. E. (2002) · Pharmacology Biochemistry and Behavior · doi:10.1016/s0091-3057(01)00687-6 · Cited by 457
MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Keereman, V., Fierens, Y., Broux, T., De Deene, Y., Lonneux, M., & Vandenberghe, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065425 · Cited by 442
Kuhl, D. E., Engel, J., Phelps, M. E., & Selin, C. (1980) · Annals of Neurology · doi:10.1002/ana.410080403 · Cited by 420
Self-citationSILENT MYOCARDIAL ISCHAEMIA DUE TO MENTAL STRESS
Deanfield, J., Kensett, M., Wilson, R., Shea, M., Horlock, P., De Landsheere, C., & Selwyn, A. (1984) · The Lancet · doi:10.1016/s0140-6736(84)91106-1 · Cited by 414
Lin, C., Itti, E., Haioun, C., Petegnief, Y., Luciani, A., Dupuis, J., Paone, G., Talbot, J.-N., Rahmouni, A., & Meignan, M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.042093 · Cited by 394
Aversive gustatory stimulation activates limbic circuits in humans
Zald, D. (1998) · Brain · doi:10.1093/brain/121.6.1143 · Cited by 384
Kuhl, D. E., Phelps, M. E., Kowell, A. P., Metter, E. J., Selin, C., & Winter, J. (1980) · Annals of Neurology · doi:10.1002/ana.410080108 · Cited by 365
Self-citationCirculatory and Metabolic Correlates of Brain Function in Normal Humans
Raichle, M. E. (1987) · Comprehensive Physiology · doi:10.1002/cphy.cp010516 · Cited by 323
Germano, G., Erel, J., Lewin, H., Kavanagh, P. B., & Berman, D. S. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00276-3 · Cited by 315
Horwitz, B., Duara, R., & Rapoport, S. I. (1984) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1984.73 · Cited by 313
History and future technical innovation in positron emission tomography
Jones, T., & Townsend, D. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011013 · Cited by 303
PET/MRI for Neurologic Applications
Catana, C., Drzezga, A., Heiss, W.-D., & Rosen, B. R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.105346 · Cited by 288
Pichler, B. J., Wehrl, H. F., Kolb, A., & Judenhofer, M. S. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.02.001 · Cited by 258
Davies, J. R., Rudd, J. H. F., Fryer, T. D., Graves, M. J., Clark, J. C., Kirkpatrick, P. J., Gillard, J. H., Warburton, E. A., & Weissberg, P. L. (2005) · Stroke · doi:10.1161/01.str.0000190896.67743.b1 · Cited by 258
Model‐based image reconstruction for four‐dimensional PET
Li, T., Thorndyke, B., Schreibmann, E., Yang, Y., & Xing, L. (2006) · Medical Physics · doi:10.1118/1.2192581 · Cited by 210
Serotonin type-1A receptor imaging in depression
Drevets, W. C., Frank, E., Price, J. C., Kupfer, D. J., Greer, P. J., & Mathis, C. (2000) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(00)00119-0 · Cited by 203
Transmission scanning in emission tomography
Bailey, D. L. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050282 · Cited by 202
Seo, Y., Mari, C., & Hasegawa, B. H. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.001 · Cited by 198
“Despite this pioneering work, the modern use of transmission imaging with external radionuclide transmission sources was not introduced for attenuation correction in SPECT [34,35] and PET [36,37] until the 1980s.”
BackgroundHuang, S.-C., Carson, R. E., Hoffman, E. J., Carson, J., MacDonald, N., Barrio, J. R., & Phelps, M. E. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.21 · Cited by 192
Self-citationAndersen, F. L., Ladefoged, C. N., Beyer, T., Keller, S. H., Hansen, A. E., Højgaard, L., Kjær, A., Law, I., & Holm, S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.042 · Cited by 190
“Attenuation correction is a pre-requisite for in-vivo PET quantification (Huang et al., 1979).”
Partial Volume Correction Strategies in PET
Rousset, O., Rahmim, A., Alavi, A., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.005 · Cited by 190
MULTIMODALITY IN VIVO IMAGING SYSTEMS: Twice the Power or Double the Trouble?
Cherry, S. R. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095728 · Cited by 188
Tracer Kinetic Modeling in PET
Carson, R. E. (2006) · Positron Emission Tomography · doi:10.1007/1-84628-007-9_6 · Cited by 186
Speculation on the Meaning of Cerebral Metabolic Hypofrontality in Schizophrenia
Weinberger, D. R., & Berman, K. F. (1988) · Schizophrenia Bulletin · doi:10.1093/schbul/14.2.157 · Cited by 183
Intercorrelations of regional cerebral glucose metabolic rates in Alzheimer's disease
Horwitz, B., Grady, C. L., Schlageter, N. L., Duara, R., & Rapoport, S. I. (1987) · Brain Research · doi:10.1016/0006-8993(87)91107-3 · Cited by 181
Effects of Long-term Smoking on Myocardial Blood Flow, Coronary Vasomotion, and Vasodilator Capacity
Campisi, R., Czernin, J., Schöder, H., Sayre, J. W., Marengo, F. D., Phelps, M. E., & Schelbert, H. R. (1998) · Circulation · doi:10.1161/01.cir.98.2.119 · Cited by 181
“Partial volume effects were corrected by use of a recovery coefficient that assumes a uniform left ventricular wall thickness of 1 cm.(14) Both the blood pool and myocardial time-activity curves were corrected for physical decay and were fitted to a previously validated two-compartment tracer kinetic model that correc…”
MethodSelf-citationPET: Physics, Instrumentation, and Scanners
Cherry, S. R., & Dahlbom, M. (2006) · PET · doi:10.1007/0-387-34946-4_1 · Cited by 181
Positron Emission Tomography Partial Volume Correction: Estimation and Algorithms
Aston, J. A. D., Cunningham, V. J., Asselin, M.-C., Hammers, A., Evans, A. C., & Gunn, R. N. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200208000-00014 · Cited by 180
Forward to the Past: The Case for Quantitative PET Imaging
Lammertsma, A. A. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.188029 · Cited by 176
An attenuated projector-backprojector for iterative SPECT reconstruction
Gullberg, G. T., Huesman, R. H., Malko, J. A., Pelc, N. J., & Budinger, T. F. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/8/004 · Cited by 173
5-HT1A receptor binding and intracerebral activity in temporal lobe epilepsy: an [18F]MPPF-PET study
Merlet, I. (2004) · Brain · doi:10.1093/brain/awh109 · Cited by 173
Cerebral blood flow in immediate and sustained anxiety
Hasler, G., Fromm, S., Alvarez, R. P., Luckenbaugh, D. A., Drevets, W. C., & Grillon, C. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.5369-06.2007 · Cited by 163
Mazziotta, J. C., Huang, S.-C., Phelps, M. E., Carson, R. E., MacDonald, N. S., & Mahoney, K. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.10 · Cited by 166
Self-citationCerebral glucose metabolic rates in normal human females versus normal males
Baxter, L. R., Mazziotta, J. C., Phelps, M. E., Selin, C. E., Guze, B. H., & Fairbanks, L. (1987) · Psychiatry Research · doi:10.1016/0165-1781(87)90028-x · Cited by 165
Self-citationKushner, M., Alavi, A., Reivich, M., Dann, R., Burke, A., & Robinson, G. (1984) · Annals of Neurology · doi:10.1002/ana.410150505 · Cited by 158
Berti (2014) · doi:10.1016/j.cpet.2013.10.006 · Cited by 152
Age, sex and laterality effects on cerebral glucose metabolism in healthy adults
Willis, M. W., Ketter, T. A., Kimbrell, T. A., George, M. S., Herscovitch, P., Danielson, A. L., Benson, B. E., & Post, R. M. (2002) · Psychiatry Research Neuroimaging · doi:10.1016/s0925-4927(01)00126-3 · Cited by 150
PET measures of amphetamine-induced dopamine release in ventral versus dorsal striatum
Drevets, W. (1999) · Neuropsychopharmacology · doi:10.1016/s0893-133x(99)00079-2 · Cited by 122
Conway, C. R., Chibnall, J. T., Gebara, M. A., Price, J. L., Snyder, A. Z., Mintun, M. A., Craig, A. D. (., Cornell, M. E., Perantie, D. C., Giuffra, L. A., et al. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.11.006 · Cited by 75
Fin, L., Bailly, P., Daouk, J., & Meyer, M. (2009) · Medical Physics · doi:10.1118/1.3152116 · Cited by 18
Metadata
- Authors
- Huang, S.-C., Hoffman, E. J., Phelps, M. E., & Kuhl, D. E.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1979-12
- Volume
- 3
- Issue
- 6
- Pages
- 804-814
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W3001275908
- Cited by
- 443
- References
- 0
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.