Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 540

The DOI matches its Crossref record.

Precise Measurement of Vertebral Mineral Content Using Computed Tomography

Cann, Christopher E., Genant, Harry K.·1980·Journal of Computer Assisted Tomography

Abstract

A precise method of measuring vertebral mineral content by computed tomography has been developed. Calibration phantoms scanned with patients are used to provide corrections for machine drifts. Advanced software manipulation of the display images is used to reposition precisely to the midportion of each vertebral body. A long-term precision of 2.8% for mineral content has been obtained in excised vertebrae in a phantom simulating the human torso.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198008000-00018

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 540

Metadata

Authors
Cann, C. E., & Genant, H. K.
Venue
Journal of Computer Assisted Tomography
Published
1980-08
Volume
4
Issue
4
Pages
493-500
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2027109535
Cited by
540
References
0
FWCI
18.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Precise Measurement of Vertebral Mineral Content Using Computed Tomography. https://app.cochat.ai/papers/10.1097/00004728-198008000-00018
The paper
Cann, C. E., & Genant, H. K. (1980). Precise Measurement of Vertebral Mineral Content Using Computed Tomography. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198008000-00018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.