Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 337

The DOI matches its Crossref record.

Quantitation in Positron Emission Computed Tomography: 5. Physical–Anatomical Effects

Mazziotta, John C., Phelps, Michael E., Plummer, David, Kuhl, David E.·1981·Journal of Computer Assisted Tomography

Abstract

The effect of neuroanatomical structure size, shape, and position versus spatial tomographic resolution on quantitation in positron computed tomography was investigated. For neuroanatomical structures, voxel sizes in excess of 3 ml exceeded the volume of most structures examined. When the voxel size exceeded structure volume, calculated recovery coefficient (fraction of the true isotope concentration measured in the image) fell to less than or equal to 42%. Partial volume effects in the plane of section analyzed by computer simulation produced errors that were largest for small, thin, irregularly shaped structures whose averaged pixel values were most different from neighboring structures. Smallest errors occurred in large, circular structures surrounded by regions of similar pixel values. Computer simulation of regional cerebral asymmetries of pixel values demonstrated that the measurement of these asymmetries was often predominated (enhanced or obliterated) by partial volume effects related to structure size and shape. Large, circular, and widely separated regional asymmetries were more easily detected at a given spatial resolution than small, thin, adjacent regions. Recommendations for error reduction and possible correction factors are provided and discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198110000-00029

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 337

Metadata

Authors
Mazziotta, J. C., Phelps, M. E., Plummer, D., & Kuhl, D. E.
Venue
Journal of Computer Assisted Tomography
Published
1981-10
Volume
5
Issue
5
Pages
734-743
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2007544558
Cited by
337
References
0
FWCI
17.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitation in Positron Emission Computed Tomography: 5. Physical–Anatomical Effects. https://app.cochat.ai/papers/10.1097/00004728-198110000-00029
The paper
Mazziotta, J. C., Phelps, M. E., Plummer, D., & Kuhl, D. E. (1981). Quantitation in Positron Emission Computed Tomography: 5. Physical–Anatomical Effects. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198110000-00029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.