The DOI matches its Crossref record.
Initial Clinical Evaluation of a Whole Body Nuclear Magnetic Resonance (NMR) Tomograph
Abstract
A nuclear magnetic resonance (NMR) imaging system is described, and preliminary results from its clinical use are presented. The properties and detection of the magnetisation due to hydrogen protons are outlined, and a rotating frame is introduced to describe the motion of the magnetisation. Radiofrequency (RF) pulses are used to rotate the magnetisation, and slice selection is achieved using a 90 degree RF pulse and a magnetic field gradient. Data acquisition and image reconstruction are explained. Three scanning sequences are described: repeated free induction decay (FID), inversion - recovery, and spin-echo. These sequences produce images whose pixel values have different dependencies on hydrogen proton density, T1 and T2. Inversion-recovery images show striking differentiation between grey and white matter in the brain. The absence of bone artifact is a significant advantage over X-ray computed tomography in the posterior fossa, where rapid repeated FID sequences can also be used to demonstrate flow effects. The considerable soft tissue contrast available with NMR is of value in demonstrating disease within the liver where T1 appears to be sensitive but relatively nonspecific diagnostic parameter. High resolution scans are of value in demonstrating the adrenal gland and spinal cord.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Field-cycling relaxometry of protein solutions and tissue: Implications for MRI
Koenig, S. H., & Brown, R. D. (1990) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(90)80008-6 · Cited by 363
Quantification of liver fat using magnetic resonance spectroscopy
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92543-7 · Cited by 332
Relaxometry of brain: Why white matter appears bright in MRI
Koenig, S. H., Brown, R. D., Spiller, M., & Lundbom, N. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140306 · Cited by 298
Metadata
- Authors
- Young, I. R., Bailes, D. R., Burl, M., Collins, A. G., Smith, D. T., McDonnell, M. J., Orr, J. S., Banks, L. M., Bydder, G. M., Greenspan, R. H., & Steiner, R. E.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1982-02
- Volume
- 6
- Issue
- 1
- Pages
- 1-18
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2090536243
- Cited by
- 190
- References
- 0
- FWCI
- 36.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Initial Clinical Evaluation of a Whole Body Nuclear Magnetic Resonance (NMR) Tomograph. https://app.cochat.ai/papers/10.1097/00004728-198202000-00001
- The paper
- Young, I. R., Bailes, D. R., Burl, M., Collins, A. G., Smith, D. T., McDonnell, M. J., Orr, J. S., Banks, L. M., Bydder, G. M., Greenspan, R. H., & Steiner, R. E. (1982). Initial Clinical Evaluation of a Whole Body Nuclear Magnetic Resonance (NMR) Tomograph. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198202000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.