Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission Tomography
The DOI matches its Crossref record.
Abstract
A contour-finding algorithm is described by which the object periphery is outlined in positron emission tomography (PET) scans. The positions of maximum slopes are determined in the projections. These positions are shown to correspond well to the borders of the activity region. By backprojecting these points in the projections into the image plane, the size and shape of the region of activity must be outlined. Cord lengths across this region are then determined for attenuation correction. The accuracy of the algorithm has been tested on 10 patients with both PET and computed tomography (CT) examinations. Points on the periphery of the skull, as determined with the contour-finding algorithm in PET, coincided with those determined by CT, with a standard deviation of 1.5 mm and a maximum deviation of 3.5 mm. In testing the influence of the skull bone on the PET values, it was found that ignoring the higher attenuation coefficient of bone, 5 mm thick, in the attenuation correction caused an error in the determination of activity of 11% peripherally and 6% centrally in the object. These errors could be reduced to less than 1% by increasing the assumed attenuating region by 4.5 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Functional anatomy of human procedural learning determined with regional cerebral blood flow and PET
Grafton, S., Mazziotta, J., Presty, S., Friston, K., Frackowiak, R., & Phelps, M. (1992) · The Journal of Neuroscience · doi:10.1523/jneurosci.12-07-02542.1992 · Cited by 607
“Each sinogram of projection data was analyzed using a boundary detection algorithm, and emission scans were reconstructed using a calculated attenuation correction method (Bergstrom et al., 1982).”
MethodChugani, H. T., Behen, M. E., Muzik, O., Juhász, C., Nagy, F., & Chugani, D. C. (2001) · NeuroImage · doi:10.1006/nimg.2001.0917 · Cited by 584
Farde, L. (1990) · Archives of General Psychiatry · doi:10.1001/archpsyc.1990.01810150013003 · Cited by 530
Nordström, A.-L., Farde, L., Wiesel, F.-A., Forslund, K., Pauli, S., Halldin, C., & Uppfeldt, G. (1993) · Biological Psychiatry · doi:10.1016/0006-3223(93)90288-o · Cited by 527
Catana, C., van der Kouwe, A., Benner, T., Michel, C. J., Hamm, M., Fenchel, M., Fischl, B., Rosen, B., Schmand, M., & Sorensen, A. G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069112 · Cited by 359
Cerebral Blood Flow in Subjects With Social Phobia During Stressful Speaking Tasks: A PET Study
Tillfors, M., Furmark, T., Marteinsdottir, I., Fischer, H., Pissiota, A., Långström, B., & Fredrikson, M. (2001) · American Journal of Psychiatry · doi:10.1176/appi.ajp.158.8.1220 · Cited by 353
Signorini, M., Paulesu, E., Friston, K., Perani, D., Colleluori, A., Lucignani, G., Grassi, F., Bettinardi, V., Frackowiak, R. S. J., & Fazio, F. (1999) · NeuroImage · doi:10.1006/nimg.1998.0381 · Cited by 265
Statistical Parametric Mapping: Assessment of Application in Children
Muzik, O., Chugani, D. C., Juhász, C., Shen, C., & Chugani, H. T. (2000) · NeuroImage · doi:10.1006/nimg.2000.0651 · Cited by 240
Zaidi, H., Montandon, M.-L., & Slosman, D. O. (2003) · Medical Physics · doi:10.1118/1.1569270 · Cited by 233
Evans, A. C., Beil, C., Marrett, S., Thompson, C. J., & Hakim, A. (1988) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1988.92 · Cited by 232
“…was performed with corrections for random events (using detector singles rate data), detector deadtime, detector efficiency variation, and attenu ation (threshold projection method; Bergstrom et ai., 1982) and for scattered events by a deconvolu tion procedure similar to that of Bergstrom et ai.”
MethodCerebral blood flow during anticipation of public speaking in social phobia: a PET study
Tillfors, M., Furmark, T., Marteinsdottir, I., & Fredrikson, M. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01396-3 · Cited by 231
“The additional interleaved scan was reconstructed to a 30-slice image set with a 20 cm coverage in axial (superior to inferior) direction (Bergström et al 1982).”
MethodGrossman, M., Mickanin, J., Onishi, K., Hughes, E., D'Esposito, M., Ding, X.-S., Alavi, A., & Reivich, M. (1996) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1996.8.2.135 · Cited by 216
Heiss, W.-D., Pawlik, G., Herholz, K., Wagner, R., Göldner, H., & Wienhard, K. (1984) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1984.30 · Cited by 210
Fredrikson, M., Furmark, T., Olsson, M. T., Fischer, H., Andersson, J., & LÅngström, B. (1998) · Psychophysiology · doi:10.1017/s0048577298001796 · Cited by 198
Gjedde, A., Wienhard, K., Heiss, W.-D., Kloster, G., Diemer, N. H., Herholz, K., & Pawlik, G. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.23 · Cited by 181
PET: Physics, Instrumentation, and Scanners
Cherry, S. R., & Dahlbom, M. (2006) · PET · doi:10.1007/0-387-34946-4_1 · Cited by 181
Kagawa, K., Chugani, D. C., Asano, E., Juhász, C., Muzik, O., Shah, A., Shah, J., Sood, S., Kupsky, W. J., Mangner, T. J., et al. (2005) · Journal of Child Neurology · doi:10.1177/08830738050200050701 · Cited by 175
Slowly progressive aphasia without generalized dementia: Studies with positron emission tomography
Chawluk, J. B., Mesulam, M. ‐., Hurtig, H., Kushner, M., Weintraub, S., Saykin, A., Rubin, N., Alavi, A., & Reivich, M. (1986) · Annals of Neurology · doi:10.1002/ana.410190112 · Cited by 165
Fueger, B. J., Czernin, J., Cloughesy, T., Silverman, D. H., Geist, C. L., Walter, M. A., Schiepers, C., Nghiemphu, P., Lai, A., Phelps, M. E., et al. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.078592 · Cited by 159
“Attenuation correction was calculated as reported previously (31).”
MethodKushner, M., Alavi, A., Reivich, M., Dann, R., Burke, A., & Robinson, G. (1984) · Annals of Neurology · doi:10.1002/ana.410150505 · Cited by 158
Adult fragile X syndrome: neuropsychology, brain anatomy, and metabolism
Schapiro, M. B., Murphy, D. G. M., Hagerman, R. J., Azari, N. P., Alexander, G. E., Miezejeski, C. M., Hinton, V. J., Horwitz, B., Haxby, J. V., Kumar, A., et al. (1995) · American Journal of Medical Genetics · doi:10.1002/ajmg.1320600603 · Cited by 85
Metadata
- Authors
- Bergström, M., Litton, J., Eriksson, L., Bohm, C., & Blomqvist, G.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1982-04
- Volume
- 6
- Issue
- 2
- Pages
- 365-372
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1986348744
- Cited by
- 214
- References
- 0
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.