CoChat

Quantitation in Positron Emission Computed Tomography: 6. Effect of Nonuniform Resolution

Hoffman, Edward J., Huang, Sung-Cheng, Plummer, David, Phelps, Michael E. · 1982 · Journal of Computer Assisted Tomography
Cited by 117

The DOI matches its Crossref record.

Abstract

The intrinsic resolution (FWHM) of coincident bismuth germanate detector pairs was measured for geometries consistent with positron emission computed tomography systems designed for brain imaging. The resolutions were measured as a function of the position in the field of view (FOV) for single slice and multislice configurations for both the image and axial resolutions. System diameters of 66 to 42 cm were simulated, and intrinsic resolution variation for image and axial dimensions for a 24 cm FOV were 14 and 32% and 24 and 39%, respectively. Measurement of axial resolutions of interplane slices of multiplane systems employing interplane septa showed resolution variations for the 24 cm FOV of as large as a factor of three. A simple model was shown to predict the dominant features of the line shapes. Images of phantoms with small axial dimensions indicate that the variations in resolution, particularly in interplane data, seriously compromise the validity of point to point comparison of information within an image or between single plane and interplane images. Serious variations in axial resolution were shown to create artifacts and degrade the image resolution. Index Terms: Emission computed tomography--Image quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198210000-00022

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 117

Metadata

Authors
Hoffman, E. J., Huang, S.-C., Plummer, D., & Phelps, M. E.
Venue
Journal of Computer Assisted Tomography
Published
1982-10
Volume
6
Issue
5
Pages
987-999
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2082732984
Cited by
117
References
0
FWCI
2.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitation in Positron Emission Computed Tomography: 6. Effect of Nonuniform Resolution. https://app.cochat.ai/papers/10.1097/00004728-198210000-00022
The paper
Hoffman, E. J., Huang, S.-C., Plummer, D., & Phelps, M. E. (1982). Quantitation in Positron Emission Computed Tomography: 6. Effect of Nonuniform Resolution. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198210000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.