The DOI matches its Crossref record.
Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique
Abstract
A method for determining flow by nuclear magnetic resonance (NMR) imaging is described. A conventional spin-echo imaging sequence is employed with the addition of balanced gradient pulses on either side of the pi radiofrequency pulse. Flow velocities in the direction orthogonal to the image plane are determined by the phase shifts in the NMR image. Experimental validation of the technique in vitro was achieved with a phantom designed to give a continuous flow of water. The flow rate measured by NMR agreed well with the volume flow rate through the phantom. In vivo, NMR flow measurements on the carotid and femoral arteries of two volunteers were compared with Doppler ultrasound results. Velocity measurements were in general agreement. Rapid changes in flow are difficult to follow with the NMR method unless particular care is taken in gradient profile design. The technique can readily be used in existing NMR imaging machines and may have a useful clinical role.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Metadata
- Authors
- Bryant, D. J., Payne, J. A., Firmin, D. N., & Longmore, D. B.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1984-08
- Volume
- 8
- Issue
- 4
- Pages
- 588-593
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1981678086
- Cited by
- 545
- References
- 0
- FWCI
- 13.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique. https://app.cochat.ai/papers/10.1097/00004728-198408000-00002
- The paper
- Bryant, D. J., Payne, J. A., Firmin, D. N., & Longmore, D. B. (1984). Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198408000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.