Simplified, Noninvasive PET Measurement of Blood-Brain Barrier Permeability
The DOI matches its Crossref record.
Abstract
Blood-brain barrier (BBB) permeability to [68Ga]EDTA was measured by positron emission tomography (PET) in four normal volunteers and in 11 patients with brain tumors. A unidirectional transfer constant, Ki, was calculated applying multiple-time graphical analysis (MTGA). This method allows the detection of backflux from brain to blood and, by generalization, the measurement of the constant Kb (brain to blood). Furthermore, the need for an independent measurement of the intravascular tracer is obviated: MTGA itself provides an estimate of the cerebral plasma volume (Vp). In the four normal volunteers the Ki was 3.0 +/- 0.8 X 10(-4) ml g-1 min-1 (mean +/- SD) and the Vp 0.034 +/- 0.007 ml g-1. A net increase in Ki up to a maximum of 121.0 X 10(-4) ml g-1 min-1 (correspondent value of Kb = 0.025 min-1) as well as an increase of Vp was observed in malignant tumors. The input function was calculated using both the [68Ga]EDTA concentration in sequential arterial blood samples and, noninvasively, the activity derived from the superior sagittal sinus image. The values of Ki and Vp from these two calculations were in good agreement. The application of MTGA to PET permits the evaluation of passage of substances across the BBB without making assumptions about the compartments in which the tracer distributes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
The blood-brain barrier in systemic inflammation
Varatharaj, A., & Galea, I. (2017) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2016.03.010 · Cited by 1,172
“…(Cramer et al., 2014) Injection of radiolabelled substances before nuclear medicine brain imaging Gallium injection positron emission tomography (Iannotti et al., 1987) Injection of radiolabelled test and BBB-impermeable reference substances into carotid artery, or antecubital vein, and…”
Larsson, H. B. W., Stubgaard, M., Frederiksen, J. L., Jensen, M., Henriksen, O., & Paulson, O. B. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160111 · Cited by 431
Heye, A. K., Culling, R. D., Valdés Hernández, M. D. C., Thrippleton, M. J., & Wardlaw, J. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.09.002 · Cited by 406
Metadata
- Authors
- Iannotti, F., Fieschi, C., Alfano, B., Picozzi, P., Mansi, L., Pozzilli, C., Punzo, A., Vecchio, G. D., Lenzi, G. L., Salvatore, M., & Conforti, P.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1987-05
- Volume
- 11
- Issue
- 3
- Pages
- 390-397
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2066586472
- Cited by
- 77
- References
- 0
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simplified, Noninvasive PET Measurement of Blood-Brain Barrier Permeability. https://app.cochat.ai/papers/10.1097/00004728-198705000-00004
- The paper
- Iannotti, F., Fieschi, C., Alfano, B., Picozzi, P., Mansi, L., Pozzilli, C., Punzo, A., Vecchio, G. D., Lenzi, G. L., Salvatore, M., & Conforti, P. (1987). Simplified, Noninvasive PET Measurement of Blood-Brain Barrier Permeability. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198705000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.