The DOI matches its Crossref record.
Three Dimensional Image Correlation of CT, MR, and PET Studies in Radiotherapy Treatment Planning of Brain Tumors
Abstract
A treatment planning system for stereotactic convergent beam irradiation of deeply localized brain tumors is reported. The treatment technique consists of several moving field irradiations in noncoplanar planes at a linear accelerator facility. Using collimated narrow beams, a high concentration of dose within small volumes with a dose gradient of 10-15%/mm was obtained. The dose calculation was based on geometrical information of multiplanar CT or magnetic resonance (MR) imaging data. The patient's head was fixed in a stereotactic localization system, which is usable at CT, MR, and positron emission tomography (PET) installations. Special computer programs for correction of the geometrical MR distortions allowed a precise correlation of the different imaging modalities. The therapist can use combinations of CT, MR, and PET data for defining target volume. For instance, the superior soft tissue contrast of MR coupled with the metabolic features of PET may be a useful addition in the radiation treatment planning process. Furthermore, other features such as calculated dose distribution to critical structures can also be transferred from one set of imaging data to another and can be displayed as three-dimensional shaded structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Automatic 3‐D model‐based neuroanatomical segmentation
Collins, D. L., Holmes, C. J., Peters, T. M., & Evans, A. C. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030304 · Cited by 974
Medical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
Strauss, L. G. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01367602 · Cited by 527
Self-citation
Metadata
- Authors
- Schad, L. R., Boesecke, R., Schlegel, W., Hartmann, G. H., Sturm, V., Strauss, L. G., & Lorenz, W. J.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1987-11
- Volume
- 11
- Issue
- 6
- Pages
- 948-954
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2058220290
- Cited by
- 170
- References
- 0
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three Dimensional Image Correlation of CT, MR, and PET Studies in Radiotherapy Treatment Planning of Brain Tumors. https://app.cochat.ai/papers/10.1097/00004728-198711000-00005
- The paper
- Schad, L. R., Boesecke, R., Schlegel, W., Hartmann, G. H., Sturm, V., Strauss, L. G., & Lorenz, W. J. (1987). Three Dimensional Image Correlation of CT, MR, and PET Studies in Radiotherapy Treatment Planning of Brain Tumors. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198711000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.