Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.

Medical image registration

Hill, Derek L G, Batchelor, Philipp G, Holden, Mark, Hawkes, David J · 2001 · Physics in Medicine and Biology

Abstract

Radiological images are increasingly being used in healthcare and medical research. There is, consequently, widespread interest in accurately relating information in the different images for diagnosis, treatment and basic science. This article reviews registration techniques used to solve this problem, and describes the wide variety of applications to which these techniques are applied. Applications of image registration include combining images of the same subject from different modalities, aligning temporal sequences of images to compensate for motion of the subject between scans, image guidance during interventions and aligning images from multiple subjects in cohort studies. Current registration algorithms can, in many cases, automatically register images that are related by a rigid body transformation (i.e. where tissue deformation can be ignored). There has also been substantial progress in non-rigid registration algorithms that can compensate for tissue deformation, or align images from different subjects. Nevertheless many registration problems remain unsolved, and this is likely to continue to be an active field of research in the future.

Overview

Integrity signals

Registry

Crossref · 10.1088/0031-9155/46/3/201

Cites

0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 123 references

Research works printed but not linked: 8

  1. 10.1002/1522-2594(200007)44:1<101::AID-MRM15>3.0.CO;2-S · doi:10.1002/1522-2594(200007)44:1<101::aid-mrm15>3.0.co;2-s
  2. 10.1016/S1361-8415(96)80006-5 · doi:10.1016/s1361-8415(96)80006-5
  3. 10.1002/(SICI)1522-712X(1995)1:4<198::AID-IGS2>3.0.CO;2-5 · doi:10.1002/(sici)1522-712x(1995)1:4<198::aid-igs2>3.0.co;2-5
  4. 10.1002/(SICI)1522-2594(200004)43:4<583::AID-MRM13>3.0.CO;2-B · doi:10.1002/(sici)1522-2594(200004)43:4<583::aid-mrm13>3.0.co;2-b
  5. Press W H, 1992
  6. Sibson R, 1978, J. R. Statist. Soc., 40, 234
  7. 10.1002/(SICI)1522-2586(199910)10:4<582::AID-JMRI12>3.0.CO;2-X · doi:10.1002/(sici)1522-2586(199910)10:4<582::aid-jmri12>3.0.co;2-x
  8. 10.1016/S1361-8415(96)80004-1 · doi:10.1016/s1361-8415(96)80004-1

Cited by

See all 2,093

Metadata

Authors
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J.
Affiliations
Guy's Hospital (GB)
Venue
Physics in Medicine and Biology
Published
2001-02-15
Volume
46
Issue
3
Pages
R1-R45
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2140139548
Cited by
2,093
References
127
Citations by year
2026: 19 · 2025: 21 · 2024: 40 · 2023: 47 · 2022: 45 · 2021: 44 · 2020: 53 · 2019: 57 · 2018: 66 · 2017: 89 · 2016: 69 · 2015: 100 · 2014: 104 · 2013: 124 · 2012: 105
FWCI
4.50
Type
journal article
Language
en
Open access
closed
Locations
  • Physics in Medicine and Biology (publishedVersion)
  • PubMed (publishedVersion)
  • UCL Discovery (University College London) (submittedVersion)
  • Research Portal (King's College London) (submittedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
Keywords
medical image registration, multimodal image fusion, motion compensation, image-guided interventions, rigid transformation, non-rigid registration, tissue deformation, temporal image sequences
MeSH terms
Algorithms, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted, Registries, Research

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Medical image registration. https://app.cochat.ai/papers/10.1088/0031-9155/46/3/201
The paper
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001). Medical image registration. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/46/3/201

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.