The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Relations of mechanical properties to density and CT numbers in human bone
Abstract
Mechanical properties of cortical and cancellous bone from eight human subjects were determined using an ultrasonic transmission technique. Raw computerized tomography (CT) values obtained from scans of the bones in water were corrected to Hounsfield units. The correlations between CT numbers and mechanical property estimated from cortical bone were found to be low (r2 < 0.2), while these relationships for cancellous bone were found to be higher (r2 > 0.6). These results suggest that CT values may be useful in predicting mechanical properties only for cancellous bone. Poor correlations were found between modulus in the radial or circumferential direction and modulus in the superior-inferior direction for cortical bone, whereas good correlations were found between modulus in the anterior-posterior direction or medial-lateral direction and modulus in the S-I direction for cancellous bone. These results indicate that modulus in the radial or circumferential direction could not be predicted from modulus in the S-I direction for cortical bone, but could be predicted for cancellous bone. The predictive capabilities of linear and power models evaluated for cancellous bone alone were approximately equal. However, the power function gives a better fit of data at the low and high density values. The specific relationships, depending on the types of bone, that predict elastic modulus from density and CT numbers were suggested for human cortical and cancellous bone. These specific correlations may help a number of researchers develop more accurate models; however, these hypotheses should be proven by further study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Stiffness of compact bone: Effects of porosity and density
Schaffler, M. B., & Burr, D. B. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90186-8 · Cited by 652
Dynamic response of bone and muscle tissue.
McElhaney, J. H. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.4.1231 · Cited by 509
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Cited by
Mechanical properties and the hierarchical structure of bone
Rho, J.-Y., Kuhn-Spearing, L., & Zioupos, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00007-1 · Cited by 2,588
Self-citationBio-CAD modeling and its applications in computer-aided tissue engineering
Sun, W., Starly, B., Nam, J., & Darling, A. (2005) · Computer-Aided Design · doi:10.1016/j.cad.2005.02.002 · Cited by 386
Fu, Q., Saiz, E., & Tomsia, A. P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.06.030 · Cited by 366
Mirzaali, M. J., Schwiedrzik, J. J., Thaiwichai, S., Best, J. P., Michler, J., Zysset, P. K., & Wolfram, U. (2016) · Bone · doi:10.1016/j.bone.2015.11.018 · Cited by 325
The dependence of transversely isotropic elasticity of human femoral cortical bone on porosity
Neil Dong, X., & Edward Guo, X. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.011 · Cited by 302
Metadata
- Authors
- Rho, J. Y., Hobatho, M. C., & Ashman, R. B.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1995-07-01
- Volume
- 17
- Issue
- 5
- Pages
- 347-355
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2046354206
- Cited by
- 822
- References
- 4
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relations of mechanical properties to density and CT numbers in human bone. https://app.cochat.ai/papers/10.1016/1350-4533(95)97314-f
- The paper
- Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995). Relations of mechanical properties to density and CT numbers in human bone. Medical Engineering & Physics. https://doi.org/10.1016/1350-4533(95)97314-f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.