The DOI matches its Crossref record.
MR Imaging of Anisotropically Restricted Diffusion of Water in the Nervous System: Technical, Anatomic, and Pathologic Considerations
Abstract
The use of MR imaging to image anisotropically restricted diffusion (ARD) of water in the nervous system is described. The theoretical basis for the use of the pulsed gradient spin echo sequences is outlined, including an estimate of the range of cell dimensions that can be studied with this technique. The importance of restricted diffusion across myelinated white matter fibre tracts is emphasised and the capacity of MR imaging to demonstrate fibre pathways as a function of their direction is illustrated. Technical developments that have been implemented include 256 x 256 spatial resolution, a wider range of diffusion times Td, and an increased range of diffusion sensitivity parameters b. Effects of these are illustrated together with the use of gradient moment nulling methods, oblique sensitisation, and a smaller set of gradient coils that enable shorter values of echo time to be used with the same value of b. The anatomical basis for ARD imaging is analysed, and association, commissural, and projection fibre tracts are demonstrated in different planes. The published literature on variations of the apparent diffusion coefficient from normal is reviewed and examples where diffusion weighted images revealed information that was not necessarily apparent with conventional sequences are illustrated. These include cases of multiple sclerosis, chronic head injury, progressive multifocal leucoencephalopathy, cerebrovascular disease, astrocytoma, and probable metastases to the brain. Imaging of ARD affords a fascinating conjunction between the microscopic movement of water, the properties of myelinated white matter fibres, gross anatomy of the brain, and changes of the diffusion of water in disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
A review of MRI findings in schizophrenia
Shenton, M. E., Dickey, C. C., Frumin, M., & McCarley, R. W. (2001) · Schizophrenia Research · doi:10.1016/s0920-9964(01)00163-3 · Cited by 2,346
Hachinski, V., Iadecola, C., Petersen, R. C., Breteler, M. M., Nyenhuis, D. L., Black, S. E., Powers, W. J., DeCarli, C., Merino, J. G., Kalaria, R. N., et al. (2006) · Stroke · doi:10.1161/01.str.0000237236.88823.47 · Cited by 1,722
Metadata
- Authors
- Hajnal, J. V., Doran, M., Hall, A. S., Collins, A. G., Oatridge, A., Pennock, J. M., oung, I. R., & Bydder, G. M.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1991-01
- Volume
- 15
- Issue
- 1
- Pages
- 1-18
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2001672324
- Cited by
- 226
- References
- 0
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR Imaging of Anisotropically Restricted Diffusion of Water in the Nervous System: Technical, Anatomic, and Pathologic Considerations. https://app.cochat.ai/papers/10.1097/00004728-199101000-00001
- The paper
- Hajnal, J. V., Doran, M., Hall, A. S., Collins, A. G., Oatridge, A., Pennock, J. M., oung, I. R., & Bydder, G. M. (1991). MR Imaging of Anisotropically Restricted Diffusion of Water in the Nervous System: Technical, Anatomic, and Pathologic Considerations. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199101000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.