Measuring Random Microscopic Motion of Water in Tissues with MR Imaging: A Cat Brain Study
The DOI matches its Crossref record.
Abstract
Cat brain images sensitized to incoherent motion by additional gradient pulses were obtained on a 4.7 T magnetic resonance unit equipped with shielded gradient coils. The apparent diffusion coefficient of water in gray and white matter was accurately determined and imaged from the signal attenuation curve obtained as a function of gradient strength. Contrast in calculated diffusion images differed from typical T2-weighted contrast. Furthermore, in gray matter and in areas containing flowing CSF the attenuation curve was found to be biexponential. These results are interpreted in terms of a simple voxel model with microcirculation and diffusion contributions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Mukherjee, P., Miller, J. H., Shimony, J. S., Conturo, T. E., Lee, B. C. P., Almli, C. R., & McKinstry, R. C. (2001) · Radiology · doi:10.1148/radiol.2212001702 · Cited by 431
The capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423
Self-citation
Metadata
- Authors
- Bihan, D. L., Moonen, C. T. W., van Zijl, P. C. M., Pekar, J., & DesPres, D.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1991-01
- Volume
- 15
- Issue
- 1
- Pages
- 19-25
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2007657884
- Cited by
- 102
- References
- 0
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring Random Microscopic Motion of Water in Tissues with MR Imaging: A Cat Brain Study. https://app.cochat.ai/papers/10.1097/00004728-199101000-00002
- The paper
- Bihan, D. L., Moonen, C. T. W., van Zijl, P. C. M., Pekar, J., & DesPres, D. (1991). Measuring Random Microscopic Motion of Water in Tissues with MR Imaging: A Cat Brain Study. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199101000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.