Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 280

The DOI matches its Crossref record.

A Computerized Brain Atlas: Construction, Anatomical Content, and Some Applications

Greitz, Torgny, Bohm, Christian, Holte, Sven, Eriksson, Lars · 1991 · Journal of Computer Assisted Tomography

Abstract

An adjustable computerized atlas of the human brain has been developed, which can be adapted to fit individual anatomy. It is primarily intended for positron emission tomography (PET) but may also be used for single photon emission CT, transmission CT, magnetic resonance imaging, and neu-roimaging-based procedures, such as stereotactic surgery and radiotherapy. The atlas is based on anatomical information obtained from brains fixed in situ soon after death. All structures have been drawn in on digitized photos of slices from one cryosectioned brain. The definition and classification of the anatomical structures and divisions are in agreement with the standard textbooks of anatomy, and the nomenclature is that of the Nomina Anatomica of 1965. The boundaries of the cortical cytoarchitectonic areas (Brodmann areas) have been determined using information from several sources, since three-dimensional literature data on their distribution are incomplete, scarce, and partly contradictory. However, no analysis of the cytoarchitectonics of the atlas brain itself has been undertaken. At present the data base contains three-dimensional representations of the brain surface, the ventricular system, the cortical gyri and sulci, as well as the Brodmann cytoarchitectonic areas. The major basal ganglia, the brain stem nuclei, the lobuli of the vermis, and the cerebellar hemispheres are also included. The computerized atlas can be used to improve the quantification and evaluation of PET data in several ways. For instance, it can serve as a guide in selecting regions of interest. It may also facilitate comparisons of data from different individuals or groups of individuals, by applying the inverse atlas transformation to PET data volume, thus relating the PET information to the anatomy of the reference atlas rather than to the patient's anatomy. Reformatted PET data from individuals can thus be averaged, and averages from different categories or different functional states of patients can be compared.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-199101000-00003

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 280

Metadata

Authors
Greitz, T., Bohm, C., Holte, S., & Eriksson, L.
Venue
Journal of Computer Assisted Tomography
Published
1991-01
Volume
15
Issue
1
Pages
26-38
ISSN
0363-8715 (ISSN-L)
OpenAlex
W4317564269
Cited by
280
References
0
FWCI
23.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Computerized Brain Atlas: Construction, Anatomical Content, and Some Applications. https://app.cochat.ai/papers/10.1097/00004728-199101000-00003
The paper
Greitz, T., Bohm, C., Holte, S., & Eriksson, L. (1991). A Computerized Brain Atlas: Construction, Anatomical Content, and Some Applications. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199101000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.