The DOI matches its Crossref record.
3D PET using a Conventional Multislice Tomograph without Septa
Abstract
A conventional multislice positron emission tomography scanner was modified to operate without interplane septa to evaluate its performance in collecting and reconstructing data in a three-dimensional (3D) format, thereby significantly increasing system sensitivity. A 3D filtered backprojection algorithm was implemented and tested, using both computer simulations and phantom measurements. No artifacts were apparent in the test images, although the algorithm was shown to lead to a 11% degradation in transaxial resolution in the outer planes. Following septa removal, sensitivity was found to increase by a factor of 7 with an increase in scatter fraction from 16 to 41%. Axial resolution degraded from 6.9 to 7.7 mm full width at half maximum at the center of the field of view. The maximum count rate without septa was 2.4 x 10(5) cps, at a concentration of 0.4 microCi/ml, compared with 1.3 x 10(5) cps at 1.5 microCi/ml with septa. Brain studies were performed with volunteers using 18F-fluorodeoxyglucose, 18F-fluorodopa, and H2 15O to compare noise-equivalent count rates and qualitatively assess image quality over a wide range of imaging conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Baxter, L. R. (1992) · Archives of General Psychiatry · doi:10.1001/archpsyc.1992.01820090009002 · Cited by 1,293
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Model-based scatter correction for fully 3D PET
Ollinger, J. M. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/012 · Cited by 393
Brain metabolic changes in major depressive disorder from pre- to post-treatment with paroxetine
Brody, A. L., Saxena, S., Silverman, D. H. S., Fairbanks, L. A., Phelps, M. E., Huang, S.-C., Wu, H.-M., Maidment, K., Baxter, L. R., & Alborzian, S. (1999) · Psychiatry Research: Neuroimaging · doi:10.1016/s0925-4927(99)00034-7 · Cited by 298
Physical performance of a positron tomograph for brain imaging with retractable septa
Spinks, T. J., Jones, T., Bailey, D. L., Townsend, D. W., Grootoonk, S., Bloomfield, P. M., Gilardi, M. C., Casey, M. E., Sipe, B., & Reed, J. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/8/002 · Cited by 293
Metadata
- Authors
- Cherry, S. R., Dahlbom, M., & Hoffman, E. J.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1991-07
- Volume
- 15
- Issue
- 4
- Pages
- 655-668
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2034034351
- Cited by
- 182
- References
- 0
- FWCI
- 12.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D PET using a Conventional Multislice Tomograph without Septa. https://app.cochat.ai/papers/10.1097/00004728-199107000-00023
- The paper
- Cherry, S. R., Dahlbom, M., & Hoffman, E. J. (1991). 3D PET using a Conventional Multislice Tomograph without Septa. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199107000-00023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.